***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Bosch Rexroth directly.***
The Bosch Rexroth DBA25H2-2X/350V (R901313446) is a sophisticated pump safety block designed for seamless integration into hydraulic systems. This pilot-operated pressure relief valve is crafted to be mounted directly onto SAE pressure ports of pumps, ensuring efficient operation and safety by limiting the operating pressure. The unit comprises a valve block and a pressure limitation screw-in cartridge valve, with the option to install a pressure switch for enhanced functionality.
The DBA25H2-2X/350V features a robust valve housing with ports for hydraulic fluid input (P) and output (P), along with an additional port (T) that connects to the tank line. The pressure limitation screw-in cartridge valve within the block manages the flow of hydraulic fluid, maintaining equilibrium and allowing for quick pressure build-up when necessary. Users can monitor operating pressures through a dedicated pressure gauge connection.
This model offers versatility through various adjustment types for setting the operating pressure, including options like a rotary knob, sleeve with hexagon and protective cap, lockable rotary knob with scale, or rotary knob with scale. It supports multiple pressure ratings to accommodate diverse system requirements.
Designed for zero-pressure startup and pump circulation, the DBA25H2-2X/350V ensures low circulation pressures due to its proximity to the pump and features a low compression volume that contributes to soft switching to depressurized circulation. Its direct flange mounting at the pump minimizes noise levels during operation.
With its compact size and component series X, this model can handle maximum operating pressures up to 350 bar and is capable of managing maximum flow rates as specified in its technical documentation. The order specifications provide additional customization options suited to various applications within hydraulic systems.
$1,818.00 USD
More are expected on April 21, 2025
Status: This product is temporarily out of stock.
Qty: Delivered as early as April 21, 2025 when ordered in
This product is eligible for factory repair.
Zero-pressure start-up and circulation of the pump Intended for direct mounting onto the SAE pressure port of the pump Low circulation pressure due to short distance Low compression volume for soft switching to depressurized circulation Quick pressure build-up 4 adjustment types for pressure adjustment, optionally
• Rotary knob
• Sleeve with hexagon and protective cap
• Lockable rotary knob with scale
• Rotary knob with scale 5 pressure ratings, optional Low noise level due to direct flange mounting at the pump
General
Pump safety blocks type DBA are pilot-operated pressure relief valves which are integrated into a block and intended to be mounted directly onto SAE pressure ports of pumps.
It is used for limiting (type DBA) the operating pressure.
Pump safety blocks generally consist of valve block (1) and pressure limitation screw-in cartridge valve type DB 20 K (2) (data sheet 25818). Optionally, a pressure switch type HED 8 (3) (data sheet 50061) can be installed on the valve block.
The valve housing is equipped with a port P for hydraulic fluid input and port P1 for hydraulic fluid output. In a branch of the through connection between these two ports, the pressure limitation screw-in cartridge valve can be found. By opening this valve, a connection to port T (tank line) is established.
At the standard model, connection diagram NG6 is covered with the cover plate (4). The pressure in the through connection (P - P1) has an effect on the main control spool (5) of the pressure limitation screw-in cartridge valve.
Via the nozzle bores (6 and 7), the pressure is at the same time applied to the poppet (8). If the pressure in port P exceeds the value set at spring (9), the poppet (8) opens against the spring (9).
Via the nozzle bores (6 and 7), the hydraulic fluid from channel P flows into the spring chamber (10) and is here internally directed via the control line (11) into the tank.
Due to the state of equilibrium at the main control spool (5), hydraulic fluid flows from channel P to channel T, maintaining the set operating pressure.
A pressure gauge connection (12) allows for the control of the operating pressure.
Pump safety block type DBA…D (with pressure switch)
The use of an electrical pressure switch type HED 8 (3) (data sheet 50061) enables activation and deactivation of an electric circuit via the control line (13).
In basic design, the control line (13) is closed with a plug screw (14).
The pressure gauge connection M and tank port T are illustrated with an offset of 90 °!
01 |
02 |
03 |
04 |
05 |
06 |
07 |
08 |
09 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
17 |
18 |
19 |
|
DBA |
2X |
/ |
Type |
||
01 |
Pump safety block (connection diagram NG6 covered with cover plate HSA 06 A 001…) |
DBA |
02 |
Without directional valve |
no code |
Size |
||
03 |
Size 16 |
15 |
Size 25 |
25 |
|
Size 32 |
30 |
|
04 |
Without directional valve |
no code |
Type of connection / SAE flange 1) |
||
05 |
Standard flange (250 … 350 bar) |
F |
High-pressure flange (350 bar) |
H |
|
Adjustment type for pressure adjustment 2) |
||
06 |
Rotary knob |
1 |
Sleeve with hexagon and protective cap |
2 |
|
Lockable rotary knob with scale |
3 7) |
|
Rotary knob with scale |
7 |
|
07 |
Without pressure switch |
– |
With mounted pressure switch type HED 8 OH… (connector according to DIN EN 175301-803, without mating connector), (data sheet 50061) |
D 3) |
|
Component series |
||
08 |
Component series 20 ... 29 (20 ... 29: unchanged installation and connection dimensions) |
2X |
Pressure rating 5) |
||
09 |
Set pressure up to 50 bar |
50 |
Set pressure up to 100 bar |
100 |
|
Set pressure up to 200 bar |
200 |
|
Set pressure up to 315 bar |
315 |
|
Set pressure up to 350 bar |
350 |
|
10 |
Without additional pressure relief valve |
no code |
11 |
Standard version |
no code |
Valve for minimum cracking pressure |
U |
|
12 |
Without directional valve |
no code |
13 |
Without manual override |
no code |
Electrical individual connection |
||
14 |
Without mating connector; connector DIN EN 175301-803 |
K4 3) |
Interface electronics |
||
15 |
Without electronics |
no code |
Nozzle fitting |
||
16 |
Fixed pumps |
|
Lateral channel closed, transverse channel open, pilot oil bore open; (standard for displacement pumps; pure DB-/DBW function) |
no code |
|
Variable displacement pumps |
||
Lateral channel closed, transverse channel open, pilot oil bore closed (e.g. for axial piston variable displacement pump type A4VSO140 with DRG controller) |
A00 |
|
Nozzle Ø0.8 mm in lateral channel, transverse channel open; pilot oil bore closed (standard for control pumps with DFR1 or DFLR controller) |
A08 4) |
|
Nozzle Ø1.0 mm in lateral channel, transverse channel open; pilot oil bore closed (for nozzle fitting of the block, refer to the circuit examples) |
A10 4) |
|
Seal material 6) |
||
17 |
NBR seals |
no code |
FKM seals |
V |
|
Type-examination procedure |
||
18 |
Without type-examination procedure |
no code |
Type-examination tested safety valve according to PED 2014/68/EU |
E |
|
19 |
Standard solenoid coil |
no code |
Solenoid coil is an approved component with UR-marking according to UL 906 (only version "6E") |
= UR |
1) Observe pressure ratings and connection dimensions! | |
2) Adjustment type for pressure switch type HED 8 in brackets! | |
3) Mating connectors, separate order | |
4) If used on variable displacement pumps with DFLR controllers, the nozzle at port X of the pump control must be removed! | |
5) The same pressure rating at pressure limitation screw-in cartridge valves type DB 20 K, pressure relief valve (sandwich plate valve) type Z(2)DB 6 and pressure switches type HED 8. | |
6) Observe compatibility of seals with hydraulic fluid used. (Other seals upon request) | |
7) H-key with material no. R900008158 is included in the scope of delivery. | |
Notice! Preferred types and standard units are contained in the EPS (standard price list).
general
Size |
16 | 25 | 32 | |||||
Earth |
Pump safety block |
DBA... |
kg |
5.4 | 5.3 | 5.4 | 6 | |
Pressure switches |
HED 8 |
kg |
0.8 | |||||
Installation position |
any | |||||||
Ambient temperature range |
NBR seals |
°C |
-30 … +80 | - | ||||
FKM seals |
°C |
- | -15 … +80 |
hydraulic
Size |
16 | 25 | 32 | |||
Maximum operating pressure |
Port P |
bar |
350 | |||
Maximum counter pressure |
Port T |
bar |
250 | |||
Minimum set pressure |
flow-dependent, see characteristic curves | |||||
Maximum set pressure |
bar |
50 100 200 315 350 |
||||
Maximum flow |
l/min |
300 | 400 | |||
Hydraulic fluid |
see table | |||||
Hydraulic fluid temperature range |
NBR seals |
°C |
-30 … +80 | - | ||
FKM seals |
°C |
- | -20 … +80 | |||
Viscosity range |
mm²/s |
10 … 800 | ||||
Maximum admissible degree of contamination of the hydraulic fluid 1) |
Class 20/18/15 according to ISO 4406 (c) |
1) | The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents faults and simultaneously increases the life cycle of the components. For the selection of the filters, see www.boschrexroth.com/filter. |
Hydraulic fluid |
Classification |
Suitable sealing materials |
Standards |
Data sheet |
|
Mineral oils |
HL, HLP |
NBR, FKM |
DIN 51524 |
90220 |
|
Bio-degradable |
Insoluble in water |
HETG |
NBR, FKM |
ISO 15380 |
90221 |
HEES |
FKM |
||||
Soluble in water |
HEPG |
FKM |
ISO 15380 |
||
Flame-resistant |
Water-free |
HFDU, HFDR |
FKM |
ISO 12922 |
90222 |
Containing water |
HFC (Fuchs Hydrotherm 46M, Petrofer Ultra Safe 620 ) |
NBR |
ISO 12922 |
90223 |
Important information on hydraulic fluids:
For further information and data on the use of other hydraulic fluids, please refer to the data sheets above or contact us. There may be limitations regarding the technical valve data (temperature, pressure range, life cycle, maintenance intervals, etc.). The ignition temperature of the hydraulic fluid used must be 40K higher than the maximum surface temperature.Flame-resistant – containing water:
Maximum pressure differential per control edge 50bar Pressure pre-loading at the tank port >20 % of the pressure differential; otherwise, increased cavitation Life cycle as compared to operation with mineral oil HL, HLP 50 … 100 %Bio-degradable and flame-resistant:
If these hydraulic fluids are used, small amounts of dissolved zinc may get into the hydraulic system.Deviating technical data’: Type-examination tested safety valves type DBA…E, component series 2X according to Pressure Equipment Directive 2014/68/EU
hydraulic
Maximum flow |
See ordering code, safety instructions and characteristic curves "Type-examination tested safety valve" | |
Hydraulic fluid |
Mineral oil (HL, HLP) according to DIN 51524-1 and DIN 51524-2 | |
Hydraulic fluid temperature range |
°C |
-10 … +60 |
Viscosity range |
mm²/s |
12 … 230 |
For applications outside these parameters, please consult us!
(measured with HLP46, ϑOil = 40 ±5 °C)
Inlet pressure dependent on the flow 2)
1) | The characteristic curves apply to an output pressure pT =0 bar in the entire flow range. |
Notice!
The characteristic curves were measured with internal pilot oil return.
Due to the internal pilot oil return, the inlet pressure increases by the output pressure present in port T.
Minimum set pressure and circulation pressure dependent on the flow 1)
Standard version
1) | The characteristic curves apply to an output pressure pT =0 bar in the entire flow range. |
Minimum set pressure and circulation pressure dependent on the flow 1)
Version “U”
1) | The characteristic curves apply to an output pressure pT =0 bar in the entire flow range. |
Safety instructions:Type-examination tested safety valves type DBA…E, component series 2X according to Pressure Equipment Directive 2014/68/EU
Maximum admissible flow q Vmax dependent on the counter pressure pT in the discharge line with internal pilot oil return
Type DBA 15 …-2X/…E
Characteristic curves for intermediate values can be generated by interpolation. Further explanations see below.
pA |
Response pressure in bar |
pT |
Maximum admissible counter pressure in the discharge line in bar (port T) (sum of all possible counter pressures; also see AD2000 data sheet A2) |
pT max |
10 % x pA (with qV = 0) according to PED 2014/68/EU |
qV max |
Maximum admissible flow in l/min |
Explanation of the diagrams (Example: type DBA 15...E): |
|
known: |
Flow of the system/accumulator that has to be secured qVmax = 100 l/min |
Set response pressure of the safety valve pA = 315 bar |
|
unknown: |
pTadmissible |
Solution: |
see arrows in diagram above |
pT admissible (100 l/min; 315 bar) = 15.75 bar |
Type DBA 25 …-2X/…E and type DBA 30 …-2X/…E
pA |
Response pressure in bar |
pT |
Maximum admissible counter pressure in the discharge line in bar (port T) (sum of all possible counter pressures; also see AD2000 data sheet A2) |
pT max |
10 % x pA (with qV = 0) according to PED 2014/68/EU |
qV max |
Maximum admissible flow in l/min |
General circuit example set-up
Arrangement of the nozzles/plugs items 17.1, 17.2 and 17.3
Circuit examples: for displacement pumps (selection)
Dimensions in mm
Required surface quality of the valve contact surface |
1 |
Name plate |
2 |
Cover plate type HSA 06 A001-3X… (data sheet 48042) |
3 |
Port X for variable displacement pump type A10VSO (otherwise closed); G1/4 |
4 |
Port M for pressure gauge; G1/4 |
5 |
Mating connector without circuitry (separate order) |
6 |
Mating connector with circuitry (separate order) |
7 |
Pressure switch type HED 8 OH… (data sheet 50061) |
8 |
Adjustment type "1" 1) |
9 |
Adjustment type "2" 1) |
10 |
Adjustment type "3" 1) |
11 |
Adjustment type "7" 1) |
12 |
Hexagon SW10 |
13 |
Space required to remove the key |
14 |
Space required to remove the mating connector |
15 |
Seal ring |
24 |
Hexagon SW30, tightening torque MA = 50 Nm (For tightening, a manual torque wrench with a tolerance ≤ 10 % must be used.) |
25 |
Lock nut SW22, tightening torque MA = 10±5 Nm |
28 |
Valve mounting bores |
Standard flanges type DBA…F…
NG |
L1 |
L2 |
L3 |
B1 |
B2 |
B3 |
B4 |
B5 |
B6 |
H1 |
H2 |
H3 |
H4 |
H5 |
ØD1 |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
|
16 | 88 | 117 | 22.2 | 47.6 | 28.5 | 45 | 80 | 110 | 105 | 24 | 47 | 22 | 60 | 37 | 11 |
25 | 88 | 115.5 | 26.2 | 52.4 | 28.5 | 45 | 80 | 110 | 105 | 24 | 47 | 22 | 60 | 37 | 11 |
32 | 108.5 | 108.5 | 30.2 | 58.7 | 30.5 | 47 | 80 | 110 | 105 | 30 | 47 | 20 | 60 | 41 | 11.5 |
High-pressure flanges type DBA…H...
NG |
L1 |
L2 |
L3 |
B1 |
B2 |
B3 |
B4 |
B5 |
B6 |
H1 |
H2 |
H3 |
H4 |
H5 |
ØD1 |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
|
16 | 88 | 117 | 23.8 | 50.8 | 28.5 | 45 | 80 | 110 | 105 | 24 | 47 | 22 | 60 | 37 | 11 |
25 | 84 | 115.5 | 27.8 | 57.2 | 28.5 | 45 | 80 | 110 | 105 | 24 | 47 | 22 | 60 | 37 | 13 |
32 | 108.5 | 108.5 | 31.8 | 66.7 | 26 | 52 | 90 | 115 | 105 | 30 | 50 | 20 | 64 | 41 | 15 |
Standard flanges type DBA…F… according to DIN ISO 6162-1 |
||||||
Size |
Line connections |
4 valve mounting screws ISO 4762 - 10.9 1) |
Tightening torqueMA in Nm 2) |
|||
P and P1 |
T |
X, M |
Part number |
|||
16 |
SAE 3/4″ |
G3/4 |
G1/4 |
M10 x 95 |
R913015585 |
52 |
25 |
SAE 1″ |
G1 |
G1/4 |
M10 x 95 |
R913015585 |
52 |
32 |
SAE 1 1/4″ |
G1 1/4 |
G1/4 |
M10 x 95 |
R913015585 |
52 |
Admissible pressures (flange connections according to DIN ISO 6121-1) |
|
in bar |
|
SAE 3/4″ |
350 |
SAE 1″ |
315 |
SAE 1 1/4″ |
250 |
1)Valve mounting screws (separate order) | |
4 hexagon socket head cap screws ISO 4762 - 10.9-flZn-240h-L | |
(with friction coefficient μtotal = 0.09 ... 0.14) |
High-pressure flanges type DBA…H… according to DIN ISO 6162-2 |
||||||
Size |
Line connections |
4 valve mounting screws ISO 4762 - 10.9 1) |
Tightening torqueMA in Nm 2) |
|||
P and P1 |
T |
X |
Part number |
|||
16 |
SAE 3/4″ |
G3/4 |
G1/4 |
M10 x 95 |
R913015585 |
52 |
25 |
SAE 1″ |
G1 |
G1/4 |
M12 x 105 |
R913000659 |
66 |
32 |
SAE 1 1/4″ |
G1 1/4 |
G1/4 |
M14 x 105 |
R913000660 |
113 |
Admissible pressures (flange connections according to DIN ISO 6121-2) |
|
in bar |
|
SAE 3/4″ |
350 |
SAE 1″ |
350 |
SAE 1 1/4″ |
350 |
1)Valve mounting screws (separate order) | |
4 hexagon socket head cap screws ISO 4762 - 10.9-flZn-240h-L | |
(with friction coefficient μtotal = 0.09 ... 0.14) |
2)Notice!
The tightening torques stated are guidelines when using screws with the specified friction coefficients and when using a manual torque wrench (tolerance ± 10 %).
Notice!
For reasons of stability, other valve mounting screws must not be used!
Depending on the operating pressure, flange height and thread depth of the pump plate, other screw lengths may be necessary!
Mating connectors for valves with connector “K4”, without circuitry, standard
3P Z4
Mating connectors for valves with connector “K4”, without circuitry, standard
3P Z4
For valves with connector “K4” according to EN 175301-803 and ISO 4400, 2-pole + PE, “large cubic connector” Mating connectors for valves with one or two solenoids (individual connection)Data sheet
Spare parts & repair
Mating connectors for valves with connector “K4”, with indicator light
3P Z5L
Mating connectors for valves with connector “K4”, with indicator light
3P Z5L
For valves with connector “K4” according to EN 175301-803 and ISO 4400, 2-pole + PE, “large cubic connector” Mating connectors for valves with one or two solenoids (individual connection)Data sheet
Spare parts & repair
Mating connectors for valves with connector “K4”, with indicator light and Zener diode suppression circuit
3P Z5L1
Mating connectors for valves with connector “K4”, with indicator light and Zener diode suppression circuit
3P Z5L1
For valves with connector “K4” according to EN 175301-803 and ISO 4400, 2-pole + PE, “large cubic connector” Mating connectors for valves with one or two solenoids (individual connection)Data sheet
Spare parts & repair
Mating connectors for valves with connector “K4”, with rectifier
3P RZ5
Mating connectors for valves with connector “K4”, with rectifier
3P RZ5
For valves with connector “K4” according to EN 175301-803 and ISO 4400, 2-pole + PE, “large cubic connector” Mating connectors for valves with one or two solenoids (individual connection)Data sheet
Spare parts & repair
Mating connectors for mechanical pressure switches with connector “K14”, without circuitry, standard
4P Z14
Mating connectors for mechanical pressure switches with connector “K14”, without circuitry, standard
4P Z14
For mechanical pressure switches with connector “K14”, according to EN 175301-803 and ISO 4400, 3-pole + PE, “large cubic connector”Data sheet
Spare parts & repair
Mating connectors for mechanical pressure switches with connector “K14”, with indicator lights at connections 2 and 3
4P Z15L
Mating connectors for mechanical pressure switches with connector “K14”, with indicator lights at connections 2 and 3
4P Z15L
For mechanical pressure switches with connector “K14”, according to EN 175301-803 and ISO 4400, 3-pole + PE, “large cubic connector”Data sheet
Spare parts & repair
Ordering code: Type-examination tested safety valves type DBA…E, component series 2X according to Pressure Equipment Directive 2014/68/EU
Size |
Type designation |
Component marking |
Maximum admissible flow qVmax in l/min with pilot oil return |
Set response overpressurep in bar |
16 |
2 3 4 5 6 7 DBA 15 ▢▢▢2X/▢▢▢E |
TÜV.SV.▢‒1001.14,4.F.G.p |
60 100 150 200 250 |
30 … 60 61 … 110 111 … 210 211 … 315 316 … 350 |
25 |
2 3 4 5 6 7 DBA 25 ▢▢▢2X/▢▢▢E |
TÜV.SV.▢‒1001.14,4.F.G.p |
70 100 150 200 300 |
30 … 60 61 … 110 111 … 210 211 … 315 316 … 350 |
32 |
2 3 4 5 6 7 DBA 30 ▢▢▢2X/▢▢▢E |
TÜV.SV.▢‒1001.14,4.F.G.p |
70 100 150 200 300 |
30 … 60 61 … 110 111 … 210 211 … 315 316 … 350 |
2 |
Standard flange (250 bar) |
F |
High-pressure flange (350 bar) |
H |
|
3 |
Hand wheel (pressure adjustment sealed, unloading or setting of a lower response pressure possible!) |
1 |
With sealed protective cap (no adjustment/unloading possible) |
2 |
|
4 |
With mounted pressure switch type HED 8 OH… (without mating connector) |
D |
5 |
Pressure in the designation is to be entered by the customer, pressure adjustment ≥ 30 ... 350 bar and possible in 5 bar steps. |
z. B. 150 |
6 |
Without additional pressure relief valve |
no code |
With mounted pressure relief valve type ZDB 6 VB…-4X/..SO2 (data sheet 25751) |
Z |
|
With mounted pressure relief valve type Z2DB 6 VC…-4X/..SO2 (data sheet 25751) |
ZZ |
|
Versions DBAW…Z(Z)E and DBAE(E)…E are only available with ordering code "A00", "A08" or "A10" |
||
7 |
NBR seals |
no code |
FKM seals |
V |
|
Value entered at the factory |
Safety instructions: Type-examination tested safety valves type DBA…E, component series 2X according to Pressure Equipment Directive 2014/68/EU
Before ordering a type-examination tested safety valve, it must be observed that for the desired response pressure p, the maximum admissible flow qVmax must be larger than the maximum possible flow of the system to be secured. In this respect, the applicable regulations must be observed! According to PED 2014/68/EU, the increase in the system pressure due to the flow must not exceed 10 % of the set response pressure (see component marking). The maximum admissible flow qVmax stated in the component marking (= numerical value instead of the character "G" in the component marking, see ordering code, type-examination tested safety valves) must not be exceeded. Discharge lines of safety valves must end in a risk-free manner. The accumulation of fluids in the discharge lines must not be possible. If a lead seal at the safety valve is removed, the approval according to the PED! The requirements of the Pressure Equipment Directives 2014/68/EU and of data sheet AD2000 A2 must be generally observed! Options DBAE/DBAEE or 2nd/3rd pressure limiting function ( 6 ) are only possible for pressure relief valves for variable displacement pumps (also see ordering code).It is imperative to observe the application notes!
In the plant, the response pressure specified in the component marking is set at a flow of 11 l/min. The maximum admissible flow stated in the component marking applies for applications without counter pressure in the discharge line (port T).Notice!
The system pressure increases by the counter pressure in the discharge line (port T) with increasing flow (observe AD2000 - data sheet A2 - item 6.3!).
To ensure that this increase in system pressure caused by the flow does not exceed the value of 10 % of the set response pressure, the admissible flow has to be reduced dependent on the counter pressure in the discharge line (port T) (see diagrams (Safety instructions, Type-examination tested safety valves).
Related Products
R900948192
$2,005.00 USD
R978918944
$1,292.00 USD
R900947912
$2,435.00 USD
R900503741
$1,279.00 USD
R900411647
$1,413.00 USD