VT-DFPE-A-2X/G24K0/2A0V/V
Manufacturer: Bosch Rexroth
Material #: R900608755
Model : VT-DFPE-A-2X/G24K0/2A0V/V
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Bosch Rexroth directly.***
The Bosch Rexroth VT-DFPE-A-2X/G24K0/2A0V/V (R900608755) is a highly specialized pilot valve designed for precision pressure and flow control within hydraulic systems. This model operates through a proportional solenoid that benefits from electrical feedback, ensuring responsive and accurate adjustments to the system it is integrated with. The control electronics for this particular unit, the VTDFPE, are specifically tailored for use with the SYHDFEE system, featuring an analog interface that provides reliable and straightforward communication between the valve and control unit.
With its robust design, this pilot valve is capable of handling a maximum operating pressure of up to 350 bar, making it suitable for demanding applications where precise fluid regulation is essential. Its integration capabilities allow for seamless operation within complex hydraulic circuits. The VT-DFPE-A-2X/G24K0/2A0V/V model's construction reflects Bosch Rexroth's commitment to engineering excellence, offering durability and performance that professionals in various fields can rely on for efficient system management and control.
$6,417.00 USD
More are expected on April 22, 2025
Status: This product is temporarily out of stock.
Qty: Delivered as early as April 22, 2025 when ordered in
This product is eligible for factory repair.
Pilot valve for the pressure and flow control system SY(H)DFE. Operation through a proportional solenoid with electrical feedback Control electronics: VT-DFPE for SY(H)DFEE → integrated, analog
01 |
02 |
03 |
04 |
05 |
06 |
07 |
08 |
09 |
10 |
11 |
||||||
VT-DFPE |
- |
- |
2X |
/ |
G24 |
K0 |
/ |
/ |
- |
* |
Series |
|||||||
01 |
Pilot valve with integrated analog electronics |
VT-DFPE |
|||||
Spool design |
|||||||
02 |
Standard (not for HFC fluids) |
A |
|||||
2-groove spool (only for replacement requirement) |
B |
||||||
4-groove spool (e.g. for HFC fluids) |
C |
||||||
03 |
Component series |
2X |
|||||
04 |
Direct voltage 24 V |
G24 |
|||||
05 |
Connector (without mating connector) 1) |
K0 |
|||||
Installation orientation connector (VT-DFP) and/or integrated electronics (see also comment on feature 6) |
|||||||
06 |
radially to the pump axis |
0 |
|||||
folded 90° in the direction of the subplate with counterclockwise direction of rotation |
1 |
||||||
folded 90° in the direction of the subplate with clockwise direction of rotation |
2 |
||||||
Additional functions: Closed-loop control |
A |
B |
C |
D |
R |
||
07 |
Switchable pressure controller (high signal) |
● |
A |
||||
Power limitation adjustable at the OBE valve |
● |
B |
|||||
Power limitation adjustable via analog input |
● |
C |
|||||
Pressure controller that can be switched off (high signal) |
● |
D |
|||||
Electronics assembly, option |
|||||||
08 |
Standard electronics with leakage oil compensation |
● |
- |
- |
● |
0 |
|
Standard electronics without leakage oil compensation |
● |
● |
● |
● |
1 |
||
Actual pressure value input |
Plug-in connector |
||||||
09 |
Current input 4...20 mA |
X1 |
C |
||||
Voltage input 0...10 V (standard) |
X1 |
V |
|||||
Voltage input 1...10 V |
X1 |
E |
|||||
Voltage input 0.5..5 V (Standard) 2) |
X2 |
F |
|||||
10 |
FKM seals suitable for mineral oils (HL, HLP) according to DIN 51524 and HFC fluids 3) |
V |
|||||
11 |
Further details in the plain text e. g. SO variant |
* |
● |
available |
- |
not available |
Note on feature 6: Installation orientation of the valve electronics
Clockwise direction of rotation, installation orientation 0 |
Clockwise direction of rotation, installation orientation 2 |
Counterclockwise direction of rotation, installation orientation 0 |
Counterclockwise direction of rotation, installation orientation 1 |
1) | Connector dependent on the valve type (see "Technical data" and "Electrical connection”). |
2) | With the SY(H)DFEn control system with analog interfaces, the plug-in connector X2 can not be used as actual pressure value input. Thus, a separate pressure transducer has to be used and connected to plug-in connector X1 in this case. |
3) | Only in connection with SYHDFE and spool design C (feature 2). |
1 |
Material number |
2 |
Serial number |
3 |
Date of production |
4 |
Production order number |
5 |
Type designation |
Accessories
Version 10/2011, enquire availability
Accessories |
Material number |
Data sheet |
Mating connector 12-pole for central connection X1 without cable (assembly kit) |
R900884671 |
08006 |
Mating connector 12-pole for central connection X1 with cable set 2 x 5 m |
R900032356 |
|
Mating connector 12-pole for central connection X1 with cable set 2 x 20 m |
R900860399 |
|
Test device VT-PDFE-1-1X/V0/0 for SY(H)DFEE and SY(H)DFEC |
R900757051 |
29689-B |
Compact power supply unit VT-NE32-1X |
R900080049 |
29929 |
Notice:
For information on the environment simulation testing for the areas of EMC (electro-magnetic compatibility), climate and mechanical load, see data sheet 30030-U.
mechanic and hydraulic
Mass |
Pump without through-drive incl. pilot valve |
m |
kg |
2.25 |
Hydraulic fluid |
Mineral oil (HL, HLP) according to DIN 51524; HFC fluids only in connection with SYHDFE control system and C spool design C (feature 2 of ordering code) | |||
Hydraulic fluid temperature range |
ϑ |
°C |
-20 … +70 | |
Maximum admissible degree of contamination of the hydraulic fluid according to ISO 4406 |
Class 18/16/13 (for particle size ≤ 4/6/14 μm) |
mechanic and hydraulic
Weight without filling quantity |
m |
kg |
2.25 |
Hydraulic fluid |
Mineral oil (HL, HLP) according to DIN 51524; HFC fluids only in connection with SYHDFE control system and C spool design C (feature 2 of ordering code) | ||
Hydraulic fluid temperature range |
ϑ |
°C |
-20 … +70 |
Maximum admissible degree of contamination of the hydraulic fluid according to ISO 4406 |
Class 18/16/13 (for particle size ≤ 4/6/14 μm) |
electrical
Operating voltage |
UB |
24 VDC +40 % –5 % | ||
Operating range (short-time operation) |
Upper limit value |
UB(t)max |
V |
35 |
Lower limit value |
UB(t)min |
V |
21 | |
Current consumption (in static control operation) |
Rated current |
Inom |
A |
0.6 |
Maximum current |
Imax |
A |
1.25 | |
Inputs |
Actual pressure value input X1; |
U or I |
Determination by means of ordering code | |
Analog current inputs, load |
RB |
100 Ω | ||
Analog voltage inputs |
RE |
≥ 50 kΩ | ||
Digital inputs |
Logic 0 |
≤ 0,6 V | ||
Logic 1 |
≥ 21 V | |||
Outputs |
pactual / UOUT1 |
UO |
0 … 10 V | |
Imax |
1,5 mA | |||
αactual / UOUT2 |
UO |
± 10 V | ||
Imax |
1,5 mA | |||
Digital outputs |
Logic 0 |
Ua < 1 V | ||
Logic 1 |
Ua ≥ UB – 5 V; 10 mA (short-circuit-proof) | |||
Ambient temperature range at the pump |
ϑ |
°C |
0 … +60 | |
Storage temperature range (pump + electronics) |
ϑ |
°C |
0 … +70 | |
Type of protection according to EN 60529 |
Pump incl. pilot valve |
IP65 with mounted and locked plug-in connectors |
mechanisch und hydraulisch
Weight without filling quantity |
m |
kg |
2.25 |
Hydraulic fluid |
Mineral oil (HL, HLP) according to DIN 51524; HFC fluids only in connection with SYHDFE control system and C spool design C (feature 2 of ordering code) | ||
Hydraulic fluid temperature range |
ϑ |
°C |
-20 … +70 |
Maximum admissible degree of contamination of the hydraulic fluid according to ISO 4406 |
Class 18/16/13 (for particle size ≤ 4/6/14 μm) |
elektrisch
Operating voltage |
UB |
24 VDC +40 % –5 % | ||
Operating range (short-time operation) |
Upper limit value |
UB(t)max |
V |
35 |
Lower limit value |
UB(t)min |
V |
21 | |
Current consumption (in static control operation) |
Rated current |
Inom |
A |
0.6 |
Maximum current |
Imax |
A |
1.25 | |
Inputs |
Actual pressure value input X1; |
U or I |
Determination by means of ordering code | |
Analog current inputs, load |
RB |
100 Ω | ||
Analog voltage inputs |
RE |
≥ 50 kΩ | ||
Digital inputs |
Logic 0 |
≤ 0,6 V | ||
Logic 1 |
≥ 21 V | |||
Outputs |
nactual / UOUT1 |
UO |
0 … 10 V | |
Imax |
1,5 mA | |||
αactual / UOUT2 |
UO |
± 10 V | ||
Imax |
1,5 mA | |||
Digital outputs |
Logic 0 |
Ua < 1 V | ||
Logic 1 |
Ua ≥ UB – 5 V; 10 mA (short-circuit-proof) | |||
Ambient temperature range at the pump |
ϑ |
°C |
0 … +60 | |
Storage temperature range (pump + electronics) |
ϑ |
°C |
0 … +70 | |
Type of protection according to EN 60529 |
Pump incl. pilot valve |
IP65 with mounted and locked plug-in connectors |
elektrisch
Operating voltage |
UB |
24 VDC +40 % –5 % | ||
Operating range (short-time operation) |
Upper limit value |
UB(t)max |
V |
35 |
Lower limit value |
UB(t)min |
V |
21 | |
Current consumption (in static control operation) |
Rated current |
Inom |
A |
0.6 |
Maximum current |
Imax |
A |
1.25 | |
Inputs |
Actual pressure value input X1; |
U or I |
Determination by means of ordering code | |
Analog current inputs, load |
RB |
100 Ω | ||
Analog voltage inputs |
RE |
≥ 50 kΩ | ||
Digital inputs |
Logic 0 |
≤ 0,6 V | ||
Logic 1 |
≥ 21 V | |||
Outputs |
pactual / UOUT1 |
UO |
0 … 10 V | |
Imax |
1,5 mA | |||
αactual / UOUT2 |
UO |
± 10 V | ||
Imax |
1,5 mA | |||
Digital outputs |
Logic 0 |
Ua < 1 V | ||
Logic 1 |
Ua ≥ UB – 5 V; 10 mA (short-circuit-proof) | |||
Ambient temperature range at the pump |
ϑ |
°C |
0 … +60 | |
Storage temperature range (pump + electronics) |
ϑ |
°C |
0 … +70 | |
Type of protection according to EN 60529 |
Pump incl. pilot valve |
IP65 with mounted and locked plug-in connectors |
mechanisch und hydraulisch
Mass |
Pump without through-drive incl. pilot valve |
m |
kg |
2.25 |
Hydraulic fluid |
Mineral oil (HL, HLP) according to DIN 51524; HFC fluids only in connection with SYHDFE control system and C spool design C (feature 2 of ordering code) | |||
Hydraulic fluid temperature range |
ϑ |
°C |
-20 … +70 | |
Maximum admissible degree of contamination of the hydraulic fluid according to ISO 4406 |
Class 18/16/13 (for particle size ≤ 4/6/14 μm) |
elektrisch
Operating voltage |
UB |
24 VDC +40 % –5 % | ||
Operating range (short-time operation) |
Upper limit value |
UB(t)max |
V |
35 |
Lower limit value |
UB(t)min |
V |
21 | |
Current consumption (in static control operation) |
Rated current |
Inom |
A |
0.6 |
Maximum current |
Imax |
A |
1.25 | |
Inputs |
Actual pressure value input X1; |
U or I |
Determination by means of ordering code | |
Analog current inputs, load |
RB |
100 Ω | ||
Analog voltage inputs |
RE |
≥ 50 kΩ | ||
Digital inputs |
Logic 0 |
≤ 0,6 V | ||
Logic 1 |
≥ 21 V | |||
Outputs |
pactual / UOUT1 |
UO |
0 … 10 V | |
Imax |
1,5 mA | |||
αactual / UOUT2 |
UO |
± 10 V | ||
Imax |
1,5 mA | |||
Digital outputs |
Logic 0 |
Ua < 1 V | ||
Logic 1 |
Ua ≥ UB – 5 V; 10 mA (short-circuit-proof) | |||
Ambient temperature range at the pump |
ϑ |
°C |
0 … +60 | |
Storage temperature range (pump + electronics) |
ϑ |
°C |
0 … +70 | |
Type of protection according to EN 60529 |
Pump incl. pilot valve |
IP65 with mounted and locked plug-in connectors |
For applications outside these parameters, please consult us!
With integrated analog electronics
Allocation of connector or mating connector and cable set
With integrated analog electronics
Allocation of connector or mating connector and cable set
Functions at pin 9
Pin |
Additional function |
Function dependent on feature 7 of the ordering code (see type key) |
Signal direction |
Type of signal |
9 |
-..A... |
Selecting a different oil volume adjustment (switch TD) |
IN |
logic 24 V |
-..B... |
Power limitation active |
OUT |
logic 24 V |
|
-..C... |
Command value of power limitation |
IN |
analog 0...10 V |
|
-..D... |
Switch off pressure controller |
IN |
logic 24 V |
1) | When using a pressure transducer with raised zero point (e.g. 4...20 mA), a voltage of –1...–2.5 V will be output in case of a cable break. |
X2: Connection of pressure transducer HM 16 (mating connector M12)
Pin |
Signal HM 16 |
Pin |
|
1 |
OUT, +UB |
2 |
n.c. |
2 |
Reference L0 |
||
3 |
IN, analog, 0.5 to 5 V DC |
5 |
n.c. |
Dimensions in mm
Valve mounting screws for all types:
4 hexagon socket head cap screws
ISO4762-M6X40-10.9-flZn-240h-L,
friction coefficient μtotal = 0.09 to 0.14 according to VDA 235-101,
Tightening torque MA = 7 Nm,
material number: R913000058
1 |
Valve housing |
2 |
Proportional solenoid with position transducer |
3b |
Mating connector for connector X1 (separate order see Accessories) |
5 |
Identical seal rings for ports P, A, and T |
6 |
Solenoid rotated by 90° (installation orientation "2") |
7 |
Connection swivel angle position sensor (rotary angle sensor VT-SWA-1-1X) |
8 |
Name plate |
9 |
Integrated electronics |
10 |
Mating connector X2 for connection of a pressure transducer HM 16 |
12 |
Space required for plug-in connection (HM 16) |
13 |
Dimension for version VT-DFPE...F (connection for HM 16 or CAN bus) |
Amending notes on the SY(H)DFE control systems can be found in the operating instructions (see section “Further information about this control system”).