A2FMM080/70AWVC4V811000-0
Manufacturer: Bosch Rexroth
Material #: R902249816
Model : A2FMM080/70AWVC4V811000-0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Bosch Rexroth directly.***
The Bosch Rexroth A2FMM080/70AWVC4V811000-0 (R902249816) is a compact high-pressure motor characterized by its robust bent-axis technology and exceptional power density. Designed for both open and closed circuit applications, this metric version motor offers a nominal pressure of up to 400 bar and can withstand maximum pressure levels of up to 450 bar. The A2FMM080/70AWVC4V811000-0 is engineered to meet diverse customer requirements through its adaptable pressure ranges, ensuring suitability for a wide range of applications.
This motor is noted for its very high total efficiency and impressive starting efficiency, which contribute to its overall performance and reliability. The bent-axis design ensures that the motor remains compact with a short installation length, making it an ideal choice for systems where space is at a premium. Additionally, it comes with an optional integrated flushing valve, enhancing its functionality and extending the motor's operational lifespan by ensuring proper heat dissipation.
With these capabilities, the Bosch Rexroth A2FMM080/70AWVC4V811000-0 stands out as a powerhouse in hydraulic systems requiring durable and efficient motors. It provides users with the assurance of consistent performance even under demanding conditions, making it a key component in driving hydraulic machinery with precision and strength.
$5,913.00 USD
Availability: 12 In Stock
Qty: Delivered as early as December 24, 2024 when ordered in
Qty: Delivered as early as May 7, 2025 when ordered in
3 pressure ranges to fit to different customer requirements and applications Very high power density Very high total efficiency High starting efficiency Robust 40° bent-axis technology Optional with integrated flushing valve Bent-axis design
1) | Only available for A2FMN |
2) | Not available for A2FMH |
3) | Not available for A2FMN |
1) | Not available for A2FMH |
Table of values
Size |
56 | 63 | 80 | 90 | 107 | 45 | 56 | 63 | 80 | 90 | 45 | 56 | 63 | 80 | 90 | |||
Version |
A2FMN | A2FMM | A2FMH | |||||||||||||||
Displacement |
Vg |
cm³ |
56.6 | 63 | 81.7 | 90.5 | 108.8 | 44.9 | 56.6 | 63 | 79.8 | 90.5 | 44.9 | 56.6 | 63 | 79.8 | 90.5 | |
Nominal pressure |
pnom |
bar |
300 | 300 | 300 | 300 | 300 | 400 | 400 | 400 | 400 | 400 | 450 | 450 | 450 | 450 | 450 | |
Maximum pressure |
pmax |
bar |
350 | 350 | 350 | 350 | 350 | 450 | 450 | 450 | 450 | 450 | 500 | 500 | 500 | 500 | 500 | |
Maximum speed |
nnom 1) |
rpm |
3750 | 3750 | 3375 | 3375 | 3000 | 5000 | 5000 | 5000 | 4500 | 4500 | 5000 | 5000 | 5000 | 4500 | 4500 | |
nmax 2) |
rpm |
4125 | 4125 | 3700 | 3700 | 3300 | 5500 | 5500 | 5500 | 5000 | 5000 | 5500 | 5500 | 5500 | 5000 | 5000 | ||
Inlet flow |
at nnom |
qV |
l/min |
212 | 236 | 276 | 305 | 326 | 225 | 283 | 315 | 359 | 407 | 225 | 283 | 315 | 359 | 407 |
Torque 3) |
at pnom |
M |
Nm |
270 | 301 | 390 | 432 | 519 | 286 | 360 | 401 | 508 | 576 | 322 | 405 | 451 | 571 | 648 |
Rotary stiffness |
c |
kNm/rad |
6.83 | 8.09 | 7.94 | 9.84 | 10.9 | 4.52 | 6.83 | 8.09 | 9.09 | 9.84 | 4.52 | 6.83 | 8.09 | 9.09 | 9.84 | |
Moment of inertia for rotary group |
JTW |
kg·m² |
0.0032 | 0.0032 | 0.0034 | 0.0054 | 0.0061 | 0.0032 | 0.0032 | 0.0032 | 0.0058 | 0.0054 | 0.0032 | 0.0032 | 0.0032 | 0.0058 | 0.0054 | |
Maximum angular acceleration |
ɑ |
rad/s² |
10000 | 12200 | 19800 | 4500 | 6000 | 5400 | 9000 | 11100 | 4500 | 4500 | 5000 | 8550 | 10500 | 4500 | 4500 | |
Case volume |
V |
l |
0.6 | 0.6 | 0.6 | 0.65 | 0.65 | 0.6 | 0.6 | 0.6 | 0.65 | 0.65 | 0.6 | 0.6 | 0.6 | 0.65 | 0.65 | |
Weight (approx.) |
m |
kg |
17 | 17 | 17 | 23 | 23 | 17 | 17 | 17 | 23 | 23 | 17 | 17 | 17 | 23 | 23 |
1) |
These values are valid at: - for the optimum viscosity range from vopt = 36 to 16 mm2/s - with hydraulic fluid based on mineral oils |
2) | Intermittent maximum speed: overspeed for unload and overhauling processest, t < 5 s and Δp < 150 bar |
3) | Torque without radial force, with radial force see table "Permissible radial and axial forces of the drive shafts" |
Note
The values in the table are theoretical values, without consideration of efficiencies and tolerances. The values are rounded. Exceeding the maximum or falling below the minimum permissible values can lead to a loss of function, a reduction in operational service life or total destruction of the axial piston unit. Other permissible limit values, such as speed variation, reduced angular acceleration as a function of the frequency and the permissible angular acceleration at start (lower than the maximum angular acceleration) can be found in data sheet 90261.Speed range
No limit to minimum speed nmin. If uniformity of motion is required, speed nmin must not be less than 50 rpm.
Determining the operating characteristics |
||
Inlet flow |
[l/min] |
|
Rotational speed |
[rpm] |
|
Torque |
[Nm] |
|
Power |
[kW] |
Key |
|
Vg |
Displacement per revolution [cm3] |
Δp |
Differential pressure [bar] |
n |
Rotational speed [rpm] |
ηv |
Volumetric efficiency |
ηhm |
Hydraulic-mechanical efficiency |
ηt |
Total efficiency (ηt = ηv • ηhm) |
Hydraulic fluids
The axial piston unit is designed for operation with mineral oil HLP according to DIN 51524.
Application instructions and requirements for hydraulic fluids should be taken from the following data sheets before the start of project planning:
90220: Hydraulic fluids based on mineral oils and related hydrocarbons
90221: Environmentally acceptable hydraulic fluids
90222: Fire-resistant, water-free hydraulic fluids (HFDR, HFDU)
90223: Fire-resistant, water-containing hydraulic fluids (HFAE, HFAS, HFB, HFC)
The axial piston unit is not suitable for operation with HFA hydraulic fluid.
Viscosity and temperature of hydraulic fluids
|
Viscosity |
Shaft |
Temperature1) |
Comment |
Cold start |
νmax ≤ 1600 mm²/s |
NBR2) |
ϑSt ≥ -40 °C |
t ≤ 3 min, without load (p ≤ 50 bar), n ≤ 1000 rpm, |
FKM |
ϑSt ≥ -25 °C |
|||
Warm-up phase |
ν = 400 … 1600 mm²/s |
|
t ≤ 15 min, p ≤ 0.7 • pnom and n ≤ 0.5 • nnom |
|
Continuous operation |
ν = 10 … 400 mm²/s3) |
NBR2) |
ϑ ≤ +78 °C |
measured at port T |
FKM |
ϑ ≤ +103 °C |
|||
νopt = 16 … 36 mm²/s |
range of optimum operating viscosity and efficiency |
|||
Short-term operation |
νmin = 7 … 10 mm²/s |
NBR2) |
ϑ ≤ +78 °C |
t ≤ 3 min, p ≤ 0.3 • pnom measured at port T |
FKM |
ϑ ≤ +103 °C |
1) | If the specified temperatures cannot be maintained due to extreme operating parameters, please contact us. |
2) | Special version, please contact us. |
3) | Equates e.g. with the VG 46 a temperature range of +5 °C to +85 °C (see selection diagram) |
Note
To reduce high temperature of the hydraulic fluid in the axial piston unit we recommend the use of a flushing and boost pressure valve (see chapter Extended functions and versions).
Selection of hydraulic fluid
Bosch Rexroth evaluates hydraulic fluids on the basis of the Fluid Rating according to the technical data sheet 90235.
Hydraulic fluids with positive evaluation in the Fluid Rating are provided in the following technical data sheet:
90245: Bosch Rexroth Fluid Rating List for Rexroth hydraulic components (pumps and motors)The hydraulic fluid should be selected so that the operating viscosity in the operating temperature range is within the optimum range (νopt; see selection diagram).
Selection diagram
Filtration of the hydraulic fluid
Finer filtration improves the cleanliness level of the hydraulic fluid, which increases the service life of the axial piston unit.
A cleanliness level of at least 20/18/15 is to be maintained according to ISO 4406.
At a hydraulic fluid viscosity of less than 10 mm²/s (e.g. due to high temperatures in short-term operation) at the drain port, a cleanliness level of at least 19/17/14 according to ISO 4406 is required.
For example, the viscosity is 10 mm²/s at:
HLP 32 a temperature of 73°C HLP 46 a temperature of 85°COperating pressure range
Pressure at working port A or B (high-pressure side) |
Definition |
||
Nominal pressure |
pnom |
see table of values |
The nominal pressure corresponds to the maximum design pressure. |
Maximum pressure |
pmax |
see table of values |
The maximum pressure corresponds to the maximum operating pressure within the single operating period. The sum of the single operating periods must not exceed the total operating period. |
Single operating period |
10 s |
||
Total operating period |
300 h |
||
Minimum pressure |
pHP min |
25 bar |
Minimum pressure on high-pressure side (port A or B) required to prevent damage to the axial piston unit. |
Minimum pressure at inlet (pump operating mode) |
pE min |
see diagram |
To prevent damage to the axial piston motor in pump mode (change of high-pressure side with unchanged direction of rotation, e.g. when braking),a minimum pressure must be guaranteed at the working port (inlet). The minimum pressure depends on the rotational speed and displacement of the axial piston unit. |
Total pressure |
pSu |
700 bar |
The summation pressure is the sum of the pressures at both work ports (A and B). |
Rate of pressure change |
Definition |
||
with integrated pressure relief valve |
RA max |
9000 bar/s |
Maximum permissible rate of pressure build-up and reduction during a pressure change over the entire pressure range. |
without pressure relief valve |
RA max |
16000 bar/s |
|
Case pressure at port T |
Definition |
||
Continuous differential pressure |
ΔpT cont |
2 bar |
Maximum averaged differential pressure at the shaft seal (case to ambient) |
Pressure peaks |
pT peak |
10 bar |
t < 0.1 s |
Note
Working pressure range valid when using hydraulic fluids based on mineral oils. Values for other hydraulic fluids, please contact us.Minimum pressure at inlet (pump operating mode)
This diagram is only valid for the optimum viscosity range of vopt = 16 to 36 mm2/sec..
If the above mentioned conditions cannot be ensured, please contact us.
Pressure definition
1) | Total operating period = t1 + t2 + ... + tn |
Rate of pressure change
Note
The service life of the shaft seal is influenced by the speed of the axial piston unit and the case pressure. The service life decreases with an increase of the mean differential pressure between the case and the ambient pressure and with a higher frequency of pressure spikes. The case pressure must be equal to or higher than the ambient pressure.Direction of flow
Direction of rotation, viewed on drive shaft |
|
clockwise |
counter-clockwise |
A to B |
B to A |
Permissible radial and axial forces of the drive shaft
Size |
56 | 63 | 80 | 90 | 107 | 45 | 56 | 63 | 80 | 90 | 45 | 56 | 63 | 80 | 90 | ||||||||
Version |
A2FMN | A2FMM | A2FMH | ||||||||||||||||||||
Drive shaft |
Code |
Z6/P6 | Z8/P8 | Z8/P8 | Z8/P8 | Z9/P9 | Z9/P9 | Z6/P6 | Z6/P6 | Z8/P8 | Z8/P8 | Z8/P8 | Z9/P9 | Z9/P9 | Z6/P6 | P6 | Z8/P8 | Z8/P8 | Z8/P8 | Z9/P9 | Z9/P9 | ||
⌀ |
mm |
30 | 35 | 35 | 35 | 40 | 40 | 30 | 30 | 35 | 35 | 35 | 40 | 40 | 30 | 30 | 35 | 35 | 35 | 40 | 40 | ||
Maximum radial force |
Fq max |
7.1 kN | 6.1 kN | 6.9 kN | 8.7 kN | 8.6 kN | 10.4 kN | 7.6 kN | 9.5 N | 8.1 N | 9.2 N | 11.6 N | 10.2 N | 11.5 N | 8.6 N | 10.7 N | 9.2 N | 10.3 N | 13.1 N | 10.2 N | 11.5 N | ||
a |
mm |
18 | 18 | 18 | 18 | 20 | 20 | 18 | 18 | 18 | 18 | 20 | 20 | 20 | 18 | 18 | 18 | 18 | 20 | 20 | 20 | ||
Permitted torque at Fq max |
Tq max |
Nm |
270 | 270 | 301 | 390 | 432 | 519 | 286 | 360 | 360 | 401 | 508 | 508 | 576 | 322 | 405 | 405 | 451 | 571 | 571 | 645 | |
Permitted differential pressure at Fq max |
Δpq max |
bar |
300 | 300 | 300 | 300 | 300 | 300 | 400 | 400 | 400 | 400 | 400 | 400 | 400 | 450 | 450 | 450 | 450 | 450 | 450 | 450 | |
Maximum axial force, when standstill or in non-pressurized conditions |
+ Fax max |
N |
0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | |
- Fax max |
N |
800 | 800 | 800 | 800 | 1000 | 1000 | 800 | 800 | 800 | 800 | 1000 | 1000 | 1000 | 800 | 800 | 800 | 800 | 1000 | 1000 | 1000 | ||
Maximum axial force, per bar operating pressure |
+ Fax max |
N/bar |
8.7 | 8.7 | 8.7 | 8.7 | 10.6 | 10.6 | 8.7 | 8.7 | 8.7 | 8.7 | 10.6 | 10.6 | 10.6 | 8.7 | 8.7 | 8.7 | 8.7 | 10.6 | 10.6 | 10.6 |
General instructions
The values given are maximum values and do not apply to continuous operation. The axial force in direction −Fax is to be avoided as the service life of the bearing is reduced. Special requirements apply in the case of belt drives. Please contact us.Effect of radial force Fq on the service life of bearings
By selecting a suitable direction of radial force Fq the load on the bearings caused by the internal rotary group forces can be reduced, thus optimizing the service life of the bearings. Recommended position of mating gear is dependent on direction of rotation. Examples:
Toothed gear drive
1 |
Direction of rotation "counter-clockwise", pressure at port B |
2 |
Direction of rotation "clockwise", pressure at port A |
3 |
Direction of rotation "bidirectional" |
Port plate 11
SAE working ports at bottom
1) | To shaft collar |
2) | Flange ISO 3019-2 |
Version |
Size |
D1 |
D3 |
D4 |
D7 |
D8 |
D9 |
D10 |
D11 |
D12 |
D13 |
D14 |
D15 |
D17 |
D18 |
D19 |
D20 |
D25 |
D26 |
D29 |
D33 |
D40 |
D41 |
D42 |
D46 |
D47 |
|
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
||
A2FMN | 56 | 125 | - 0.025 | 172.7 | 122 | 160 | 20 | 10 | 32 | 30 | 86 | 148.7 | 125 | 148.7 | 30 | 126.2 | 121.5 | 93.2 | 150 | 145 | 13.5 | 147 | 23.8 | 50.8 | 19 | 75 | 25 |
63 | 125 | - 0.025 | 172.7 | 122 | 160 | 20 | 10 | 32 | 30 | 86 | 148.7 | 125 | 148.7 | 30 | 126.2 | 121.5 | 93.2 | 150 | 145 | 13.5 | 147 | 23.8 | 50.8 | 19 | 75 | 25 | |
80 | 125 | - 0.025 | 172.7 | 122 | 160 | 20 | 10 | 32 | 30 | 86 | 148.7 | 125 | 148.7 | 30 | 126.2 | 121.5 | 93.2 | 150 | 145 | 13.5 | 147 | 23.8 | 50.8 | 19 | 75 | 25 | |
90 | 140 | - 0.025 | 198.5 | 142 | 180 | 20 | 10 | 32 | 29 | 101.5 | 171.5 | 145 | 171.5 | 30 | 145.5 | 127 | 111 | 165 | 160 | 13.5 | 165 | 27.8 | 57.2 | 25 | 84 | 25 | |
107 | 140 | - 0.025 | 198.5 | 142 | 180 | 20 | 10 | 32 | 29 | 101.5 | 171.5 | 145 | 171.5 | 30 | 145.5 | 127 | 111 | 165 | 160 | 13.5 | 165 | 27.8 | 57.2 | 25 | 84 | 25 | |
A2FMM | 45 | 125 | - 0.025 | 172.7 | 122 | 160 | 20 | 10 | 32 | 30 | 86 | 148.7 | 125 | 148.7 | 30 | 126.2 | 121.5 | 93.2 | 150 | 145 | 13.5 | 147 | 23.8 | 50.8 | 19 | 75 | 25 |
56 | 125 | - 0.025 | 172.7 | 122 | 160 | 20 | 10 | 32 | 30 | 86 | 148.7 | 125 | 148.7 | 30 | 126.2 | 121.5 | 93.2 | 150 | 145 | 13.5 | 147 | 23.8 | 50.8 | 19 | 75 | 25 | |
63 | 125 | - 0.025 | 172.7 | 122 | 160 | 20 | 10 | 32 | 30 | 86 | 148.7 | 125 | 148.7 | 30 | 126.2 | 121.5 | 93.2 | 150 | 145 | 13.5 | 147 | 23.8 | 50.8 | 19 | 75 | 25 | |
80 | 140 | - 0.025 | 198.5 | 142 | 180 | 20 | 10 | 32 | 29 | 101.5 | 171.5 | 145 | 171.5 | 30 | 145.5 | 127 | 111 | 165 | 160 | 13.5 | 165 | 27.8 | 57.2 | 25 | 84 | 25 | |
90 | 140 | - 0.025 | 198.5 | 142 | 180 | 20 | 10 | 32 | 29 | 101.5 | 171.5 | 145 | 171.5 | 30 | 145.5 | 127 | 111 | 165 | 160 | 13.5 | 165 | 27.8 | 57.2 | 25 | 84 | 25 | |
A2FMH | 45 | 125 | - 0.025 | 172.7 | 122 | 160 | 20 | 10 | 32 | 30 | 86 | 148.7 | 125 | 148.7 | 30 | 126.2 | 121.5 | 93.2 | 150 | 145 | 13.5 | 147 | 23.8 | 50.8 | 19 | 75 | 25 |
56 | 125 | - 0.025 | 172.7 | 122 | 160 | 20 | 10 | 32 | 30 | 86 | 148.7 | 125 | 148.7 | 30 | 126.2 | 121.5 | 93.2 | 150 | 145 | 13.5 | 147 | 23.8 | 50.8 | 19 | 75 | 25 | |
63 | 125 | - 0.025 | 172.7 | 122 | 160 | 20 | 10 | 32 | 30 | 86 | 148.7 | 125 | 148.7 | 30 | 126.2 | 121.5 | 93.2 | 150 | 145 | 13.5 | 147 | 23.8 | 50.8 | 19 | 75 | 25 | |
80 | 140 | - 0.025 | 198.5 | 142 | 180 | 20 | 10 | 32 | 29 | 101.5 | 171.5 | 145 | 171.5 | 30 | 145.5 | 127 | 111 | 165 | 160 | 13.5 | 165 | 27.8 | 57.2 | 25 | 84 | 25 | |
90 | 140 | - 0.025 | 198.5 | 142 | 180 | 20 | 10 | 32 | 29 | 101.5 | 171.5 | 145 | 171.5 | 30 | 145.5 | 127 | 111 | 165 | 160 | 13.5 | 165 | 27.8 | 57.2 | 25 | 84 | 25 |
Port plate 02
SAE working ports at side, opposite
1) | To shaft collar |
2) | Flange ISO 3019-2 |
Version |
Size |
D1 |
D3 |
D4 |
D7 |
D8 |
D9 |
D10 |
D11 |
D12 |
D13 |
D14 |
D15 |
D17 |
D18 |
D19 |
D20 |
D25 |
D26 |
D29 |
D33 |
D40 |
D41 |
D42 |
D46 |
D47 |
|
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
||
A2FMN | 56 | 125 | - 0.025 | 172.7 | 127.5 | 160 | 20 | 10 | 32 | 30 | 86 | 148.7 | 125 | 148.7 | 30 | 126.2 | 123 | 93.2 | 150 | 145 | 13.5 | 141 | 23.8 | 50.8 | 19 | 75 | 25 |
63 | 125 | - 0.025 | 172.7 | 127.5 | 160 | 20 | 10 | 32 | 30 | 86 | 148.7 | 125 | 148.7 | 30 | 126.2 | 123 | 93.2 | 150 | 145 | 13.5 | 141 | 23.8 | 50.8 | 19 | 75 | 25 | |
80 | 125 | - 0.025 | 172.7 | 127.5 | 160 | 20 | 10 | 32 | 30 | 86 | 148.7 | 125 | 148.7 | 30 | 126.2 | 123 | 93.2 | 150 | 145 | 13.5 | 141 | 23.8 | 50.8 | 19 | 75 | 25 | |
90 | 140 | - 0.025 | 198.5 | 148.5 | 180 | 20 | 10 | 32 | 29 | 101.5 | 171.5 | 145 | 171.5 | 30 | 145.5 | 127 | 111 | 165 | 160 | 13.5 | 159 | 27.8 | 57.2 | 25 | 84 | 25 | |
107 | 140 | - 0.025 | 198.5 | 148.5 | 180 | 20 | 10 | 32 | 29 | 101.5 | 171.5 | 145 | 171.5 | 30 | 145.5 | 127 | 111 | 165 | 160 | 13.5 | 159 | 27.8 | 57.2 | 25 | 84 | 25 | |
A2FMM | 45 | 125 | - 0.025 | 172.7 | 127.5 | 160 | 20 | 10 | 32 | 30 | 86 | 148.7 | 125 | 148.7 | 30 | 126.2 | 123 | 93.2 | 150 | 145 | 13.5 | 141 | 23.8 | 50.8 | 19 | 75 | 25 |
56 | 125 | - 0.025 | 172.7 | 127.5 | 160 | 20 | 10 | 32 | 30 | 86 | 148.7 | 125 | 148.7 | 30 | 126.2 | 123 | 93.2 | 150 | 145 | 13.5 | 141 | 23.8 | 50.8 | 19 | 75 | 25 | |
63 | 125 | - 0.025 | 172.7 | 127.5 | 160 | 20 | 10 | 32 | 30 | 86 | 148.7 | 125 | 148.7 | 30 | 126.2 | 123 | 93.2 | 150 | 145 | 13.5 | 141 | 23.8 | 50.8 | 19 | 75 | 25 | |
80 | 140 | - 0.025 | 198.5 | 148.5 | 180 | 20 | 10 | 32 | 29 | 101.5 | 171.5 | 145 | 171.5 | 30 | 145.5 | 127 | 111 | 165 | 160 | 13.5 | 159 | 27.8 | 57.2 | 25 | 84 | 25 | |
90 | 140 | - 0.025 | 198.5 | 148.5 | 180 | 20 | 10 | 32 | 29 | 101.5 | 171.5 | 145 | 171.5 | 30 | 145.5 | 127 | 111 | 165 | 160 | 13.5 | 159 | 27.8 | 57.2 | 25 | 84 | 25 | |
A2FMH | 45 | 125 | - 0.025 | 172.7 | 127.5 | 160 | 20 | 10 | 32 | 30 | 86 | 148.7 | 125 | 148.7 | 30 | 126.2 | 123 | 93.2 | 150 | 145 | 13.5 | 141 | 23.8 | 50.8 | 19 | 75 | 25 |
56 | 125 | - 0.025 | 172.7 | 127.5 | 160 | 20 | 10 | 32 | 30 | 86 | 148.7 | 125 | 148.7 | 30 | 126.2 | 123 | 93.2 | 150 | 145 | 13.5 | 141 | 23.8 | 50.8 | 19 | 75 | 25 | |
63 | 125 | - 0.025 | 172.7 | 127.5 | 160 | 20 | 10 | 32 | 30 | 86 | 148.7 | 125 | 148.7 | 30 | 126.2 | 123 | 93.2 | 150 | 145 | 13.5 | 141 | 23.8 | 50.8 | 19 | 75 | 25 | |
80 | 140 | - 0.025 | 198.5 | 148.5 | 180 | 20 | 10 | 32 | 29 | 101.5 | 171.5 | 145 | 171.5 | 30 | 145.5 | 127 | 111 | 165 | 160 | 13.5 | 159 | 27.8 | 57.2 | 25 | 84 | 25 | |
90 | 140 | - 0.025 | 198.5 | 148.5 | 180 | 20 | 10 | 32 | 29 | 101.5 | 171.5 | 145 | 171.5 | 30 | 145.5 | 127 | 111 | 165 | 160 | 13.5 | 159 | 27.8 | 57.2 | 25 | 84 | 25 |
Drive shafts
Overview of available drive shafts
Splined shaft DIN 5480
1) | Center bore according to DIN 332 (thread according to DIN 13) |
2) | For size 80, pressure range "M" and "H": ⌀45 mm |
Parallel keyed shaft DIN 6885
1) | Center bore according to DIN 332 (thread according to DIN 13) |
2) | For size 80, pressure range "M" and "H": ⌀45 mm |
Ports
Size |
56 | 63 | 80 | 90 | 107 | 45 | 56 | 63 | 80 | 90 | 45 | 56 | 63 | 80 | 90 | ||
Version |
A2FMN | A2FMM | A2FMH | ||||||||||||||
A, B |
Working port |
Size |
3/4 in | 1 in | 3/4 in | 1 in | 3/4 in | 1 in | |||||||||
Standard |
Dimensions according to SAE J518 | ||||||||||||||||
Fastening thread |
M10 × 1,5; 17 mm deep | M12 × 1,75; 17 mm deep | M10 × 1,5; 17 mm deep | M12 × 1,75; 17 mm deep | M10 × 1,5; 17 mm deep | M12 × 1,75; 17 mm deep | |||||||||||
State on delivery |
With protective cover (must be connected) | ||||||||||||||||
T1 |
Drain port |
Size |
M18 × 1,5; 12 mm deep | ||||||||||||||
Standard 1) |
DIN 3852 | ||||||||||||||||
State on delivery 2) |
Plugged (observe installation instructions) | ||||||||||||||||
T2 |
Drain port |
Size |
M18 × 1,5; 12 mm deep | ||||||||||||||
Standard 1) |
DIN 3852 | ||||||||||||||||
State on delivery 2) |
With protective cover (observe installation instructions) |
1) | The spot face can be deeper than specified in the appropriate standard. |
2) | Unless otherwise specified. Other layouts on request. |
A2FMN
Size |
56 | 63 | 80 | 90 | 107 | ||
Drive shafts |
Code |
Z6/P6 | Z8/P8 | Z8/P8 | Z8/P8 | Z9/P9 | Z9/P9 |
A2FMM
Size |
45 | 56 | 63 | 80 | 90 | |||
Drive shafts |
Code |
Z6/P6 | Z6/P6 | Z8/P8 | Z8/P8 | Z8/P8 | Z9/P9 | Z9/P9 |
A2FMH
Size |
45 | 56 | 63 | 80 | 90 | |||
Drive shafts |
Code |
Z6/P6 | P6 | Z8/P8 | Z8/P8 | Z8/P8 | Z9/P9 | Z9/P9 |
Flushing and boost-pressure valve
In a closed circuit, the integrated flushing and boost-pressure valve is used for heat dissipation and to safeguard the minimum boost pressure.
Hydraulic fluid is directed from the respective low-pressure side into the motor housing. This is then fed into the reservoir, together with the leakage. The removed hydraulic fluid must be replaced by cooled hydraulic fluid supplied by the boost pump.
Cracking pressure of pressure retention valve
(observe when setting the primary valve)
fixed setting: 16 bar
Switching pressure of flushing spool Δp
8±1 bar
Circuit diagram
Flushing flow qv
Orifices can be used to adjust the flushing flows as required. The following information is based on:
ΔpND = pND – pG = 25 bar und ν = 10 mm2/s
(pND = low pressure, pG = case pressure)
Size |
Flushing flow qv |
Orifice-⌀ |
l/min |
mm |
|
all |
2.6 |
1.0 |
6 |
1.5 |
|
7.4 |
1.7 |
|
8,5 |
1.8 |
|
11.4 |
2.3 |
|
12.5 |
3 |
Pressure relief valve
The MHDB pressure relief valves (see data sheets 64602 and 64612) protect the hydraulic motor from overload. As soon as the set cracking pressure is reached, the hydraulic fluid flows from the high-pressure side to the low-pressure side.
The pressure relief valves are only available in conjunction with the working ports 07 and 09 (for the counterbalance valve for mounting to working ports 07 see next page).
Setting range of cracking pressure: 50 up to 420 bar
For versions “with pressure sequencing stage” 09S, a higher pressure setting can be implemented by connecting an external pilot pressure of 25 up to 30 bar at port PSt.
When ordering, state in plain text:
Version without pressure boost facility 09R
Version with pressure boost facility 09S
Permissible input flow or pressure in case of port plate with pressure-relief valves
Size |
Code |
pnom |
pmax |
qV |
|
Motor |
MHDB |
bar |
bar |
l/min |
|
45 … 90 | 22 | 09R, 09S | 350 | 420 | 240 |
Dimensions
Size |
D3 |
D14 |
D16 |
D17 |
D18 |
D19 |
D20 |
D38 |
D39 |
D40 |
D41 |
D42 |
D46 |
|
Motor |
MHDB |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
45, 56, 63 | 22 | 206 | 120 | 74 | 32.5 | 182 | 75 | 163 | 137 | 130 | 23.8 | 50.8 | 19 | 75 |
80, 90 | 225.5 | 128 | 73 | 31.5 | 203 | 80 | 184.5 | 127 | 145 | 27.8 | 57.2 | 25 | 75 |
Ports
Size |
45, 56, 63 | 80, 90 | ||
A, B |
Working port |
Size |
3/4 in | 1 in |
Standard |
Dimensions according to SAE J518 | |||
S1 |
Boost port |
Size |
M22 × 1.5; 14 mm deep | M26 × 1.5; 16 mm deep |
Standard 1) |
DIN 3852 | |||
State on delivery |
With protective cover (must be connected) | |||
PSt |
Pilot pressure port |
Size |
G 1/4 | |
MA, MB |
Measuring port pressure A, B |
Size |
M20 × 1.5; 14 mm deep | |
Standard 1) |
DIN 3852 | |||
State on delivery |
Plugged |
1) | The spot face can be deeper than specified in the appropriate standard. |
Counterbalance valve BVD
Function
Counterbalance valves for travel drives and winches should reduce the danger of overspeed and cavitation of axial piston motors in open circuits. Cavitation occurs if, during braking, when going downhill or during the load-lowering process, the motor speed is greater than it should be for the given inlet flow and thus the supply pressure falls sharply.
If the supply pressure falls below the level specified for the relevant counterbalance valve, the counterbalance spool moves into the closed position. The cross-sectional area of the counterbalance valve return passage is then reduced, creating a bottleneck in the return flow of the hydraulic fluid. The pressure increases and brakes the motor until the rotational speed of the motor reaches the specified value for the given inlet flow.
Notice
BVD available in sizes 45 to 90. The counterbalance valve must be ordered additionally. We recommend ordering the counterbalance valve and the motor as a set. Order example: A2FMM90/70NWVN4Z907W000 + BVD20F27S/41B–V03K16D0400S12 The counterbalance valve does not replace the mechanical service brake and holding brake. Observe the detailed notes on the BVD counterbalance valve contained in data sheet 95522 For the design of the brake release valve, we must know the following data for the mechanical holding brake: the cracking pressure the volume of the brake spool between minimum stroke (brake closed) and maximum stroke (brake released with 21 bar) the required closing time for a warm device (oil viscosity approx. 15 mm2/sec)Permissible input flow or pressure in case of port plate with counterbalance valves
Size |
Code |
pnom |
pmax |
qV |
|
Motor |
BVD |
bar |
bar |
l/min |
|
45 … 90 | 20 | 07W | 350 | 400 | 220 |
Fahrbremsventil BVD..F
Anwendungsmöglichkeit:
Fahrantrieb bei MobilbaggernExample schematic for travel drive on wheeled excavators
A2FMM90/70NWVN4Z907W000 + BVD20F27S/41B–V03K16D0400S12
BVD...W winch counterbalance valve
Application possibilities:
Winch drives in cranes (BVD) Track drive in excavator crawlers (BVD)
Example circuit diagram for winch drive in cranes
A2FMM90/70NWVN4Z907W000 + BVD20W27L/41B-V01K00D0600S00
Dimensions
Size |
D3 |
D14 |
D17 |
D20 |
D33 |
D34 |
D35 |
D46 |
|
Motor |
Counterbalance valve |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
45, 56, 63 | BVD20..17 | 205 | 193 | 32.5 | 163 | 98 | 139 | 140.5 | 75 |
80, 90 | BVD20..17 | 226.5 | 201 | 31.5 | 184.5 | 98 | 139 | 140.5 | 75 |
Ports
Size |
45, 56, 63 | 80, 90 | ||
A, B |
Working port |
Size |
3/4 in | 1 in |
Standard |
Dimensions according to SAE J518 | |||
S |
Boost port |
Size |
M22 × 1.5; 14 mm deep | |
Standard 1) |
DIN 3852 | |||
State on delivery |
Plugged | |||
Br |
Brake release port |
Size |
M12 × 1.5 | |
Standard 1) |
DIN 3852 | |||
State on delivery |
With protective cover (must be connected) | |||
Gext |
Brake release port |
Size |
M12 × 1.5 | |
Standard 1) |
DIN 3852 | |||
State on delivery |
Plugged | |||
MA, MB |
Measuring port pressure A, B |
Size |
M12 × 1,5; 12 mm deep | |
Standard 1) |
DIN 3852 | |||
State on delivery |
Plugged |
1) | The spot face can be deeper than specified in the appropriate standard. |
Mounting the counterbalance valve
When delivered, the counterbalance valve is fastened to the motor with two tacking screws (transport lock). The tacking screws may not be removed while mounting the working lines. If the counterbalance valve and motor are delivered separately, the counterbalance valve must first be fastened to the motor connection plate using the provided tacking screws. The counterbalance valve is finally mounted to the motor by fitting the SAE flange.
The screws to be used and the instructions for mounting can be found in the instruction manual.
Speed sensors DSA and DSM
The speed sensors DSA respectively DSM scan contactless a specific spline on the rotary group and thus generate an output signal with constant amplitude and a frequency proportional to the motor speed. In addition to the speed also the direction of rotation is detected. The sensor is mounted on the port provided for this purpose with one mounting bolt.
The versions A2F...A and A2F...N (“prepared for speed sensor”, i.e. without sensor) is equipped with the splines on the rotary group needed for future speed measurement. On deliveries without sensor, the port is plugged with a pressure-resistant cover.
Technical data and further specifications of the sensor can be found in the relevant data sheets 95133 (DSA) respectively 95132 (DSM).
We recommend ordering the fixed motor A2F complete with mounted sensor.
DSA speed sensor mounted
Motor |
Number of teeth |
N1 |
N3 |
N4 |
|
Version |
Size |
mm |
mm |
mm |
|
A2FMN | 56 … 80 | 47 | 32 | 96.6 | 54.6 |
90 … 107 | 53 | 32 | 108.4 | 58.8 | |
A2FMM A2FMH |
45 … 63 | 47 | 32 | 96.6 | 54.6 |
80 … 90 | 53 | 32 | 108.4 | 58.8 |
DSM speed sensor mounted (code M)
Motor |
Number of teeth |
N1 |
N2 |
N3 |
N4 |
|
Version |
Size |
mm |
mm |
mm |
mm |
|
A2FMN | 56 … 80 | 47 | 18.4 | 94.8 | 61.2 | 70.3 |
90 … 107 | 53 | 18.4 | 99.5 | 72.6 | 75 | |
A2FMM A2FMH |
45 … 63 | 47 | 18.4 | 94.8 | 61.2 | 70.3 |
80 … 90 | 53 | 18.4 | 99.5 | 72.6 | 75 |
Installation information
General information
During commissioning and during operation, the axial piston unit must be filled with hydraulic fluid and bled. This must also be observed during longer standstill as the axial piston unit might drain itself via the hydraulic lines. Complete filling and bleeding must especially be ensured with the “Drive shaft upwards” installation position as there is, for example, the risk of running dry. The leakage in the housing area must be discharged to the tank via the highest-located drain port (T1, T2). If one joint drain line is used for several units, it is to be ensured that the relevant housing pressure is not exceeded. The joint drain line must be dimensioned so that the maximum admissible housing pressure of all connected units is not exceeded in any operating state, particularly during cold start. If this is not possible, separate drain lines have to be laid, if necessary. In order to achieve favorable noise values, all connection lines are to be decoupled using elastic elements and over-tank installation is to be avoided. The tank line must lead into the tank below the minimum liquid level in every operating state.Installation position
See the following examples 1 to 8.
Further installation positions are possible upon request. Recommended installation position: 1 and 2.
Note
For installation position 4 and 8 "shaft upwards" an air bleed port R is required (specify in plain text when ordering, special version).
Below-tank installation (standard)
Below-tank installation is at hand if the axial piston unit is installed below the minimum liquid level outside the tank.
Installation position |
Air bleeding |
Filling |
1 |
‒ |
T1 |
2 |
‒ |
T2 |
3 |
‒ |
T1 |
4 |
R |
T2 |
Above-reservoir installation
Above-reservoir installation means that the axial piston unit is installed above the minimum fluid level of the reservoir.
Recommendation for installation position 8 (drive shaft upward): A check valve in the drain line (cracking pressure 0,5 bar) can prevent draining of the pump housing.
Installation position |
Air bleeding |
Filling |
5 |
F |
T1 (F) |
6 |
F |
T2 (F) |
7 |
F |
T1 (F) |
8 |
R |
T2 (F) |
Key |
|
F |
Filling / Air bleeding |
R |
Air bleed port |
T1, T2 |
Tank port |
ht min |
Minimum required immersion depth (200 mm) |
hmin |
Minimum required spacing to reservoir bottom (100 mm) |
Note: Connection F is part of the external piping and must be provided on the customer side to simplify the filling and bleeding. |
Note
Connection F is part of the external piping and must be provided on the customer side to simplify the filling and bleeding.General project planning notes
The axial piston unit is designed to be used in open and closed circuits. The project planning, installation and commissioning of the axial piston unit require the involvement of qualified skilled personnel. Before using the axial piston unit, please read the corresponding instruction manual completely and thoroughly. If necessary, request it from Bosch Rexroth. Before finalizing your design, request a binding installation drawing. The specified datas and notes must be observed. Preservation: Our axial piston units are supplied as standard with preservative protection for a maximum of 12 months. If longer preservative protection is required (maximum 24 months), please specify this in plain text when placing your order. The preservation times are valid under optimal storage conditions. Details of these conditions can be found in the data sheet 90312 or the instruction manual. Not all versions of the product are approved for use in a safety function according to ISO 13849. Please consult the responsible contact person at Bosch Rexroth if you require reliability parameters (e.g. MTTFD) for functional safety. A pressure relief valve is to be provided in the hydraulic system. Observe the instructions in the instruction manual regarding tightening torques of connection threads and other threaded joints used. The notes in the instruction manual on tightening torques of the port threads and other screw joints must be observed. The ports and fastening threads are designed for the permissible maximum pressure pmax (see instruction manual). The machine or system manufacturer must ensure that the connecting elements and lines correspond to the specified operating conditions (pressure, flow, hydraulic fluid, temperature) with the necessary safety factors. The working ports and function ports are designated only to accommodate hydraulic lines.During and shortly after operation, there is a risk of burns on the axial piston unit. Take appropriate safety measures (e.g. by wearing protective clothing).
Related Products
R902239651
$6,319.00 USD
R902163802
$10,694.00 USD
R902205978
$9,599.00 USD
R902218941
$7,412.00 USD
R902232682