***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Bosch Rexroth directly.***
The Bosch Rexroth H-4WMM16D7X/F (R900927098) is a high-quality, direct-operated directional spool valve designed for precise manual control of hydraulic flow. This valve features a robust housing, a hand lever for actuation, and one or two return springs that ensure reliable return to the neutral or initial position when the lever is released. The H-4WMM16D7X/F is characterized by its ease of operation, with the hand lever directly manipulating the control spool through a socket and bolt mechanism, allowing users to swiftly change the flow direction as needed.
This model comes with detent functionality, which securely locks the control spool in any of its designated positions, providing stable operation during extended use. It offers multiple spool positions for versatile application in various hydraulic systems. Designed with industrial standards in mind, this valve has porting patterns conforming to DIN form A and ISO standards.
The H-4WMM16D7X/F can withstand maximum operating pressures up to 315 bar and can handle maximum flow rates of up to 160 liters per minute, making it suitable for a wide range of demanding applications. The actuation mechanism is protected against contamination and humidity, ensuring long-term durability and consistent performance even in harsh environments. Additionally, the head end with the actuation mechanism is designed for easy exchange without requiring disassembly of the entire valve unit.
For enhanced functionality and monitoring capabilities, this model can be equipped with inductive position switches and proximity sensors that offer contactless detection of spool position. With these features combined into one compact package, the Bosch Rexroth H-4WMM16D7X/F provides reliable manual control over hydraulic systems for various applications where precision and durability are paramount.
$2,296.00 USD
More are expected on April 11, 2025
Status: This product is temporarily out of stock.
Qty: Delivered as early as April 11, 2025 when ordered in
This product is eligible for factory repair.
Direct operated directional spool valve with hand lever actuation Porting pattern according to DIN 24340 form A and ISO 4401 with spring return or detent, optional Actuation mechanism protected against contamination and humidity ingress Head end with actuation mechanism exchangeable without disassembly of the valve Inductive position switch and proximity sensors (contactless)
Valves type WMM are manually actuated directional spool valves. They control the start, stop and direction of a flow and basically consist of housing (1), hand lever (2), control spool (3) and one or two return springs (4).
When de-energized, the control spool (3) is held in the central position or in the initial position by the return springs (4). The control spool (3) is actuated directly by the hand lever (2). By means of a socket and the bolt (5), it acts directly on the control spool (3) which is thereby moved from its rest position to the desired end position.
When the hand lever (2) has been reset to spool position zero, the return spring (4) pushes the control spool (3) back to its rest position again.
Type H-4WMM../F.. (with detent)
This version is a directional valve with 2 or 3 spool positions and a detent (6) which locks all spool positions.
Type H-4WMM 16 E 7X/…
Type H-4WMM 16 E 7X/F… (with detent)
01 |
02 |
03 |
04 |
05 |
06 |
07 |
08 |
09 |
10 |
||
H |
– |
4 |
WMM |
/ |
* |
01 |
Maximum operating pressure 350 bar |
H |
02 |
4 main ports |
4 |
Actuation |
||
03 |
Hand lever |
WMM |
04 |
Size 16 |
16 |
Size 25 |
22 |
|
Size 32 |
32 |
|
05 |
Spool symbol, e. g. C, E etc., see Symbols |
|
06 |
NG16 and 25 – Component series 70 to 79 (70 to 79: unchanged installation and connection dimensions) |
7X |
NG32 – Component series 30 to 39 (30 to 39: unchanged installation and connection dimensions) |
5X |
|
07 |
With spring return |
no code |
With detent |
F |
|
Spool position monitoring (NG16 and 25 only) |
||
08 |
Without position switch |
no code |
Monitored spool position "a" |
QMAG24 |
|
Monitored spool position "b" |
QMBG24 |
|
Monitored rest position |
QM0G24 |
|
Seal material |
||
09 |
NBR seals |
no code |
FKM seals (other seals upon request) Observe compatibility of seals with hydraulic fluid used. |
V |
|
10 |
Further details in the plain text |
* |
Preferred types and standard units are contained in the EPS (standard price list).
general
Size |
16 | 25 | 32 | ||
Weight (approx.) |
kg |
8 | 12.2 | 49 | |
Operating force |
with detent (approx.) |
N |
75 | 105 | 100 |
with spring return (max.) |
N |
75 | 105 | 150 | |
Installation position |
any | ||||
Ambient temperature range |
NBR seals |
°C |
-30 … +80 | ||
FKM seals |
°C |
-20 … +80 | |||
Actuation angle from the central position 1) |
2 x |
° |
26 | 24.5 | 25 |
1) | see Unit dimensions |
hydraulic
Size |
16 | 25 | 32 | ||
Maximum operating pressure |
Port A |
bar |
350 | ||
Port B |
bar |
350 | |||
Port P |
bar |
350 | |||
Port T |
bar |
250 1) | 250 2) | ||
Maximum flow |
l/min |
300 | 450 | 1100 | |
Hydraulic fluid |
see table | ||||
Hydraulic fluid temperature range |
NBR seals |
°C |
-30 … +80 | ||
FKM seals |
°C |
-20 … +80 | |||
Viscosity range |
mm²/s |
2.8 … 380 | |||
Maximum admissible degree of contamination of the hydraulic fluid 3) |
Class 20/18/15 according to ISO 4406 (c) | ||||
Flow cross-section |
Symbol Q (A/B → T) |
mm² |
32 | 78 | 116 |
Symbol V (A/B → T) |
mm² |
32 | 73 | 136 | |
Symbol V (P → A/B) |
mm² |
32 | 84 | 120 | |
Symbol W (A/B → T) |
mm² |
6 | 10 | 20 |
1) | With a tank pressure > 160bar, the leakage oil has to be discharged via port L! |
2) | With a tank pressure > 160 bar, the leakage oil has to be discharged via port Y! |
3) | The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents faults and simultaneously increases the life cycle of the components. For the selection of the filters, see www.boschrexroth.com/filter. |
Hydraulic fluid |
Classification |
Suitable sealing materials |
Standards |
|
Mineral oil |
HL, HLP |
FKM, NBR |
DIN 51524 |
|
Bio-degradable |
Insoluble in water |
HEES (synthetic esters) |
FKM |
VDMA 24568 |
HETG (rape seed oil) |
FKM, NBR |
|||
Soluble in water |
HEPG (polyglycols) |
FKM |
VDMA 24568 |
|
Other hydraulic fluids on request |
Inductive position switch type QM: electrical connection
The electric connection is realized via a 4-pole mating connector (separate order) with connection thread M12 x 1.
electrical
Connection voltage (DC voltage) |
V |
24 | ||
Voltage tolerance (connection voltage) |
+30 %/-15 % | |||
Admissible residual ripple |
% |
≤ 10 | ||
Max. load capacity |
mA |
400 | ||
Switching outputs |
PNP transistor outputs, load between switching outputs and GND | |||
Pinout |
1 |
V |
24 | |
2, 4 |
Switching output |
mA |
400 | |
3 |
Earthing (GND) |
V |
0 |
For applications outside these parameters, please consult us!
(measured with HLP46, ϑOil = 40 ±5 °C)
Δp-qV characteristic curves
Size 16
Symbol |
Direction of flow |
||||
P – A |
P – B |
A – T |
B – T |
P – T |
|
E, D, Y |
1 |
1 |
1 |
3 |
– |
F |
2 |
2 |
3 |
3 |
– |
G, T |
5 |
1 |
3 |
7 |
6 |
H, C, Q |
2 |
2 |
3 |
3 |
– |
V, Z |
2 |
2 |
3 |
3 |
– |
J, K, L |
1 |
1 |
3 |
3 |
– |
M, W |
2 |
2 |
4 |
3 |
– |
R |
2 |
2 |
4 |
– |
– |
U |
1 |
1 |
4 |
7 |
– |
S |
4 |
4 |
4 |
– |
8 |
Performance limits
(measured with HLP46, ϑOil = 40 ±5 °C)
Attention!
The switching function of the valves is independent from the filtration due to the adhesive effect. To achieve the specified admissible flows, a full flow filtration with 25 μm is recommended. The flow forces acting within the valves also influence the flow performance.
With 4-way directional valves, the specified flows are therefore valid for normal operation with 2 directions of flow (e. g. from P to A and simultaneous return flow from B to T). If there is only one direction of flow, the admissible flow may be significantly lower (e. g. if a 4-way directional valve is used as a 3-way directional valve due to blocked port A or B).
NG16
2-spool position valve – qV max |
|||||
Symbol |
Operating pressure pmax in bar |
||||
70 bar |
140 bar |
210 bar |
280 bar |
350 bar |
|
With spring return |
|||||
C |
300 l/min |
300 l/min |
300 l/min |
260 l/min |
220 l/min |
D |
300 l/min |
300 l/min |
210 l/min |
190 l/min |
160 l/min |
K |
300 l/min |
300 l/min |
200 l/min |
150 l/min |
130 l/min |
Z |
300 l/min |
240 l/min |
190 l/min |
170 l/min |
150 l/min |
With detent |
|||||
C, D, K, Z |
300 l/min |
300 l/min |
300 l/min |
300 l/min |
300 l/min |
NG16
3-spool position valve – qV max |
|||||
Symbol |
Operating pressure pmax in bar |
||||
70 bar |
140 bar |
210 bar |
280 bar |
350 bar |
|
With spring return |
|||||
E, H, J, L, M, Q, R, U, W |
300 l/min |
300 l/min |
300 l/min |
300 l/min |
300 l/min |
F, P |
300 l/min |
300 l/min |
210 l/min |
190 l/min |
170 l/min |
G, S, T |
300 l/min |
300 l/min |
220 l/min |
210 l/min |
180 l/min |
V |
300 l/min |
260 l/min |
200 l/min |
180 l/min |
170 l/min |
With detent |
|||||
E, H, J, L, M, Q, R, U, W |
300 l/min |
300 l/min |
300 l/min |
300 l/min |
300 l/min |
F, P |
300 l/min |
300 l/min |
280 l/min |
230 l/min |
230 l/min |
G, S, T |
300 l/min |
300 l/min |
230 l/min |
230 l/min |
230 l/min |
V |
300 l/min |
300 l/min |
250 l/min |
230 l/min |
230 l/min |
(measured with HLP46, ϑOil = 40 ±5 °C)
Δp-qV characteristic curves
NG25
Symbol |
Direction of flow |
|||||
P – A |
P – B |
A – T |
B – T |
P – T |
B – A |
|
E |
2 |
2 |
1 |
4 |
– |
– |
F |
1 |
2 |
1 |
2 |
4 |
– |
G |
2 |
2 |
2 |
4 |
6 |
– |
H |
2 |
2 |
1 |
3 |
2 |
– |
J |
2 |
2 |
1 |
3 |
– |
– |
L |
2 |
2 |
1 |
2 |
– |
– |
M |
2 |
2 |
1 |
4 |
– |
– |
P |
2 |
2 |
1 |
4 |
6 |
– |
Q |
2 |
2 |
1 |
4 |
– |
– |
R |
1 |
2 |
1 |
– |
– |
5 |
T |
2 |
2 |
2 |
4 |
5 |
– |
U |
2 |
2 |
1 |
4 |
– |
– |
V |
2 |
2 |
1 |
4 |
– |
– |
W |
2 |
2 |
1 |
3 |
– |
– |
4 |
Spool symbol L central position A – T |
6 |
Spool symbol U central position B – T |
Performance limits
(measured with HLP46, ϑOil = 40 ±5 °C)
Attention!
The switching function of the valves is independent from the filtration due to the adhesive effect. To achieve the specified admissible flows, a full flow filtration with 25 μm is recommended. The flow forces acting within the valves also influence the flow performance.
With 4-way directional valves, the specified flows are therefore valid for normal operation with 2 directions of flow (e. g. from P to A and simultaneous return flow from B to T). If there is only one direction of flow, the admissible flow may be significantly lower (e. g. if a 4-way directional valve is used as a 3-way directional valve due to blocked port A or B).
NG25
2-spool position valve – qV max |
|||||
Symbol |
Operating pressure pmax in bar |
||||
70 bar |
140 bar |
210 bar |
280 bar |
350 bar |
|
With spring return |
|||||
C |
450 l/min |
300 l/min |
250 l/min |
200 l/min |
180 l/min |
D |
350 l/min |
300 l/min |
275 l/min |
250 l/min |
200 l/min |
K |
200 l/min |
150 l/min |
140 l/min |
130 l/min |
120 l/min |
Z |
300 l/min |
270 l/min |
240 l/min |
220 l/min |
200 l/min |
With detent |
|||||
C, D, K, Z |
450 l/min |
450 l/min |
450 l/min |
450 l/min |
450 l/min |
NG25
3-spool position valve – qV max |
|||||
Symbol |
Operating pressure pmax in bar |
||||
70 bar |
140 bar |
210 bar |
280 bar |
350 bar |
|
With spring return |
|||||
E, J, L, M, Q, R, U, W |
450 l/min |
450 l/min |
450 l/min |
450 l/min |
450 l/min |
F |
450 l/min |
250 l/min |
200 l/min |
135 l/min |
110 l/min |
G, T |
450 l/min |
330 l/min |
290 l/min |
230 l/min |
180 l/min |
H |
450 l/min |
450 l/min |
400 l/min |
400 l/min |
350 l/min |
P |
450 l/min |
310 l/min |
240 l/min |
215 l/min |
150 l/min |
V |
450 l/min |
310 l/min |
280 l/min |
270 l/min |
200 l/min |
With detent |
|||||
E, F, G, H, J, L, M, P, Q, R, T, U, W |
450 l/min |
450 l/min |
450 l/min |
450 l/min |
450 l/min |
V |
450 l/min |
450 l/min |
400 l/min |
350 l/min |
300 l/min |
(measured with HLP46, ϑOil = 40 ±5 °C)
Δp-qV characteristic curves
Size 32
Symbol |
Direction of flow |
|||||
P – A |
P – B |
A – T |
B – T |
P – T |
B – A |
|
E |
1 |
1 |
2 |
3 |
– |
– |
G |
6 |
5 |
6 |
7 |
7 |
– |
R |
1 |
1 |
2 |
– |
– |
4 |
S |
– |
– |
– |
– |
9 |
8 |
T |
6 |
5 |
6 |
7 |
7 |
– |
W |
1 |
1 |
2 |
3 |
– |
4 |
10 |
all other spool symbols |
Performance limits
(measured with HLP46, ϑOil = 40 ±5 °C)
Attention!
The switching function of the valves is independent from the filtration due to the adhesive effect. To achieve the specified admissible flows, a full flow filtration with 25 μm is recommended. The flow forces acting within the valves also influence the flow performance.
With 4-way directional valves, the specified flows are therefore valid for normal operation with 2 directions of flow (e. g. from P to A and simultaneous return flow from B to T). If there is only one direction of flow, the admissible flow may be significantly lower (e. g. if a 4-way directional valve is used as a 3-way directional valve due to blocked port A or B).
Size 32
2-spool position valve – qV max |
|||||
Symbol |
Operating pressure pmax in bar |
||||
70 bar |
140 bar |
210 bar |
280 bar |
350 bar |
|
With spring return |
|||||
C |
1100 l/min |
1040 l/min |
860 l/min |
800 l/min |
700 l/min |
D |
1100 l/min |
1040 l/min |
540 l/min |
480 l/min |
420 l/min |
K |
1100 l/min |
1040 l/min |
860 l/min |
500 l/min |
450 l/min |
Z |
1100 l/min |
1040 l/min |
860 l/min |
700 l/min |
650 l/min |
With detent |
|||||
C, D, K, Z |
1100 l/min |
1040 l/min |
860 l/min |
750 l/min |
680 l/min |
Size 32
3-spool position valve – qV max |
|||||
Symbol |
Operating pressure pmax in bar |
||||
70 bar |
140 bar |
210 bar |
280 bar |
350 bar |
|
With spring return |
|||||
E, J, L, M, Q, R, U, W |
1100 l/min |
1040 l/min |
860 l/min |
750 l/min |
680 l/min |
F, G, S, T, H, P |
900 l/min |
900 l/min |
800 l/min |
650 l/min |
450 l/min |
V |
1100 l/min |
1000 l/min |
680 l/min |
500 l/min |
450 l/min |
With detent |
|||||
E, F, G, H, J, L, M, P, Q, R, S, T, U, V, W |
1100 l/min |
1040 l/min |
860 l/min |
750 l/min |
680 l/min |
1) | only NG16 and 32 |
NG16
Dimensions in mm
1 |
Spool position “a” |
2 |
Spool position “b” |
3 |
Spool position "0" |
4 |
Name plate |
5 |
2 locking pins Ø3 |
6 |
Identical seal rings for ports A, B, P, and T |
7 |
Identical seal rings for ports L, X and Y |
8.1 |
Dimension 3 spool position valve |
8.2 |
Dimension 2 spool position valve with spring return |
9 |
machined valve contact surface |
10 |
Porting pattern according to DIN 24340 form A16 and ISO 4401-07-07-0-05 |
Subplates according to data sheet RE 45056
(separate order)
G 172/01 (G3/4)
G 174/01 (G1)
G 174/08 (flange)
Valve mounting screws (separate order)
4 hexagon socket head cap screws
ISO 4762 - M10 x 60 - 10.9-flZn-240h-L
Friction coefficient µtotal = 0.09 to 0.14,
tightening torque MA = 75 Nm,
material no. R913000116
2 hexagon socket head cap screws ISO 4762 - M6 x 60 - 10.9,
friction coefficient µtotal = 0.09 to 0.14,
tightening torque MA = 12.5 Nm
material no. R913000115
1 |
Spool position “a” |
2 |
Spool position “b” |
3 |
Spool position "0" |
4 |
Name plate |
5 |
2 locking pins Ø6 |
6 |
Identical seal rings for ports A, B, P, and T |
7 |
Identical seal rings for ports X and Y |
9 |
machined valve contact surface |
10 |
Porting pattern according to DIN 24340 form A25 and ISO 4401-08-08-0-05 |
Subplates according to data sheet RE 45058, 45059
(separate order)
G 150/01 (G3/4)
G 151/01 (G1)
G 154/01 (G1 1/4)
G 156/01 (G1 1/2)
Valve mounting screws (separate order)
6 hexagon socket head cap screws
ISO 4762 - M12 x 60 - 10.9-flZn-240h-L
Friction coefficient µtotal = 0.09 to 0.14,
tightening torque MA = 130 Nm,
material no. R913000121
Size 32
Dimensions in mm
1 |
Spool position “a” |
2 |
Spool position “b” |
3 |
Spool position "0" |
4 |
Name plate |
5 |
2 locking pins Ø6 |
6 |
Identical seal rings for ports A, B, P, and T |
7 |
Identical seal rings for ports X and Y |
8.1 |
Dimension for 2 and 3 spool position valve with detent and 3 spool position valve with spring return |
8.2 |
Dimension 2 spool position valve with spring return |
9 |
machined valve contact surface |
10 |
Porting pattern according to DIN 24340 form A32 and ISO 4401-10-09-0-05 |
11 |
Diversion plate |
Subplates according to data sheet RE 45060
(separate order)
G 157/01 (G1 1/2)
G 157/02 (M48 x 2)
G 158/10 (flange)
Valve mounting screws (separate order)
6 hexagon socket head cap screws
ISO 4762 - M20 x 80 - 10.9-flZn-240h-L
Friction coefficient µtotal = 0.09 to 0.14,
tightening torque MA = 160 Nm,
material no. R901035246
Spool position monitoring
Inductive position switch type QM
Dimensions in mm
1) | For dimensions, see valve dimensions |
Inductive position switch type QM, 4WMM
Dimensions in mm
Notice:
The dimensions are nominal dimensions which are subject to tolerances.
Size |
16 | 25 | |
H |
mm |
34 | 37 |
Related Products
R978890882
$533.00 USD
R901489722
$1,143.00 USD
R978002842
$1,444.00 USD
R978904566
$568.00 USD
R900921641