***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Bosch Rexroth directly.***
The Bosch Rexroth M-SR 8 KE30-1X (R900348329) is a high-quality check valve, designed in a cartridge format for seamless integration into hydraulic systems. This direct-acting poppet valve ensures leak-free blocking in one direction, providing reliable performance in controlling fluid flow. It's crafted to withstand a maximum operating pressure of 315 bar (4569 psi) and can accommodate a maximum flow rate of 30 l/min (7.93 gpm), making it suitable for a wide range of applications that require precise fluid control.
The M-SR 8 KE30-1X is part of the MSR product family and is notable for its robust construction and the use of NBR as the sealing material, ensuring durability and compatibility with various hydraulic fluids such as HL, HLP, and HFC. This model does not come with a pressure presetting feature, allowing users to adjust the cracking pressures according to their specific requirements optionally.
Designed for installation in block designs, it can be utilized as an angle valve or a straight-through valve depending on the system's needs. Its compact size and component series X designation indicate that it is part of Bosch Rexroth's commitment to standardized dimensions for ease of replacement and maintenance.
In summary, the Bosch Rexroth M-SR 8 KE30-1X check valve offers versatility and reliability for hydraulic systems requiring controlled flow directions under high-pressure conditions. Its cartridge design allows for easy integration while providing various options to meet different operational demands.
$215.00 USD
Availability: 5 In Stock
Qty: Delivered as early as January 10, 2025 when ordered in
Qty: Delivered as early as March 31, 2025 when ordered in
This product is eligible for factory repair.
Check valve, cartridge design
Unpacked Weight: 0.0277 kg
For installation in block designs• As angle valve• As straight-through valve Leakage-free blocking in one direction Various cracking pressures, optional
Maximum operating pressure 420 bar (6000 psi) |
Maximum flow 35 l/min (9,3 gpm) |
Data Sheet | Download Data Sheet |
Max. pressure | 420 |
Product family classification | Check valve, cartridge design |
Productgroup ID | 9,10,11,12,13,14 |
Product family type | M-SR |
Ports number | 2 |
Sealing material | NBR |
Pressure setting | 3 |
Product type | M-SR |
Max. flow | 35 |
Nominal flow | 35 |
Pressure pre-setting | Without pressure pre-setting |
Direct - Pilot | Direct acting |
Product family | Check |
Spool Poppet | Poppet type |
Weight | 0.0277 |
Hydraulic fluid | HL,HLP,HFC |
Hydraulic fluid | HL,HLP,HFC |
01 |
02 |
03 |
04 |
|
05 |
06 |
|
07 |
08 |
M-SR |
|
|
|
– |
1X |
|
/ |
|
* |
01 |
Check valve, cartridge design |
M-SR |
Size |
||
02 |
Size 6 (not version "KE") |
6 |
Size 8 |
8 |
|
Size 10 |
10 |
|
Size 15 |
15 |
|
Size 20 |
20 |
|
Size 25 |
25 |
|
Size 30 |
30 |
|
Unit design |
||
03 |
Angle valve |
KE |
Straight-through valve |
KD |
|
Cracking pressure |
||
04 |
0 bar, without spring (not version "KD") |
00 |
0,2 bar |
02 |
|
0.5 bar (standard) |
05 |
|
1,5 bar |
15 |
|
3,0 bar |
30 |
|
5,0 bar |
50 |
|
05 |
Component series 10 ... 19 (10 ... 19: unchanged installation and connection dimensions) |
1X |
Orifice in channel B (version "KD" only) |
||
06 |
Without orifice |
no code |
Core hole M4 |
B00 |
|
Nozzle Ø 1.0 mm |
B10 |
|
Nozzle Ø 1.2 mm |
B12 |
|
Seal material (observe compatibility of seals with hydraulic fluid used, see "Technical data") (version "KE" only) |
||
07 |
NBR seals |
no code |
FKM seals |
V |
|
08 |
Further details in the plain text |
* |
general
Size |
6 | 8 | 10 | 15 | 20 | 25 | 30 | ||
Weight |
Angle valve "KE" |
kg |
- | 0.03 | 0.05 | 0.08 | 0.14 | 0.32 | 0.47 |
Straight-through valve "KD" |
kg |
0.05 | 0.1 | 0.2 | 0.25 | 0.3 | |||
Installation position |
any | ||||||||
Ambient temperature range |
NBR seals |
°C |
-20 … +80 | ||||||
FKM seals |
°C |
-20 … +80 | |||||||
MTTFD values according to EN ISO 13849 1) |
150 Years |
1) | For further details, see data sheet 08012 and 90294 |
hydraulic
Size |
6 | 8 | 10 | 15 | 20 | 25 | 30 | ||
Maximum operating pressure |
bar |
420 | |||||||
Cracking pressure |
See characteristic curves | ||||||||
Maximum flow |
l/min |
15 | 35 | 50 | 120 | 200 | 300 | 400 | |
Hydraulic fluid |
see table "Hydraulic fluid" | ||||||||
Hydraulic fluid temperature range |
NBR seals |
°C |
-30 … +80 | ||||||
FKM seals |
°C |
-20 … +80 | |||||||
Viscosity range |
mm²/s |
2.8 … 500 | |||||||
Maximum admissible degree of contamination of the hydraulic fluid, cleanliness class according to ISO 4406 (c) 1) |
Class 20/18/15 |
1) | The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents faults and simultaneously increases the life cycle of the components. For the selection of the filters, see www.boschrexroth.com/filter. |
Hydraulic fluid |
Classification |
Suitable sealing materials |
Standards |
Data sheet |
|
Mineral oils |
HL, HLP |
NBR, FKM |
DIN 51524 |
90220 |
|
Bio-degradable |
Insoluble in water |
HETG |
FKM |
ISO 15380 |
90221 |
HEES |
FKM |
||||
Soluble in water |
HEPG |
FKM |
ISO 15380 |
||
Flame-resistant |
Water-free |
HFDU (glycol base) |
FKM |
ISO 12922 |
90222 |
HFDU (ester base) |
FKM |
||||
Containing water |
HFC (Fuchs Hydrotherm 46M, Petrofer Ultra Safe 620) |
NBR |
ISO 12922 |
90223 |
|
Important information on hydraulic fluids: For more information and data on the use of other hydraulicfluids, please refer to the data sheets above or contact us. There may be limitations regarding the technical valve data (temperature, pressure range, life cycle, maintenance intervals, etc.). Flame-resistant - containing water: Life cycle as compared to operation with mineral oil HL, HLP 30 … 100%. Maximum hydraulic fluid temperature 60 °C |
For applications outside these parameters, please consult us!
Angle valve (measured with HLP46, ϑOil = 40 ±5 °C)
Pressure differential Δp dependent on the flow qV at cracking pressure
Size 8
Pressure differential Δp dependent on the flow qV at cracking pressure
Size 10
Pressure differential Δp dependent on the flow qV at cracking pressure
Size 15
Pressure differential Δp dependent on the flow qV at cracking pressure
Size 20
Pressure differential Δp dependent on the flow qV at cracking pressure
Size 25
Pressure differential Δp dependent on the flow qV at cracking pressure
Size 30
Straight-through valve (measured with HLP46, ϑOil = 40 ±5 °C)
Pressure differential Δp dependent on the flow qV at cracking pressure
Size 6
Pressure differential Δp dependent on the flow qV at cracking pressure
Size 8
Pressure differential Δp dependent on the flow qV at cracking pressure
Size 10
Pressure differential Δp dependent on the flow qV at cracking pressure
Size 15
Pressure differential Δp dependent on the flow qV at cracking pressure
Size 20
Pressure differential Δp dependent on the flow qV at cracking pressure
Size 25
Pressure differential Δp dependent on the flow qV at cracking pressure
Size 30
With spring
Without spring
Angle valve "KE"
Dimensions in mm
Straight-through valve "KD"
Dimensions in mm
1) | For dimensions, see installation bores |
NG |
L-0,1 |
mm |
|
6 | - |
8 | 36.3 |
10 | 39.3 |
15 | 45.8 |
20 | 55.3 |
25 | 74.3 |
30 | 83.3 |
1 |
Plug screws, separate order, see "Accessories" |
2 |
Seat with -60 °C shrink-fitted |
3 |
Poppet stroke |
Installation bores
Installation bore: Angle valve "KE" – plug screw according to ZN 10001
Dimensions in mm
1) | Dimensions for countersinking the screw head. For lower installation of the installation kit, dimension T7 has to be extended accordingly. |
2) | Depth of fit |
3) | Pipe thread "G" according to ISO 228/1 |
1 |
Range for outlet bore |
NG |
pN |
ØD1 |
ØD2 |
D3 |
ØD4H8 |
ØD5 |
ØD6H7 |
T1 |
T2 |
T3 |
T4 |
T5 |
T6 |
T7 |
X |
Z |
||
bar |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
||
8 | 420 | 23 | 17.1 | G3/8 | 14 | 8 | 13 | 48.5 | + 0.1 | 47.5 | 38.5 | 20 | 15 | 12 | 6 | + 0.5 | 18 | 0.05 |
10 | 420 | 28 | 21.4 | G1/2 | 18 | 10 | 17 | 53.5 | + 0.1 | 52.5 | 43.5 | 24 | 18 | 14 | 6 | + 0.5 | 19 | 0.05 |
15 | 420 | 33 | 26.8 | G3/4 | 24 | 15 | 22 | 62 | + 0.1 | 60.5 | 50 | 26 | 20.5 | 16 | 6 | + 0.5 | 24 | 0.05 |
20 | 420 | 41 | 33.8 | G1 | 30 | 20 | 28 | 71.5 | + 0.1 | 70 | 56.5 | 26 | 20.5 | 16 | 7 | + 0.5 | 30 | 0.05 |
25 | 250 | 51 | 42.5 | G1 1/4 | 38 | 25 | 36 | 90.5 | + 0.1 | 88 | 72.5 | 28 | 22 | 16 | 7 | + 0.5 | 43 | 0.1 |
30 | 250 | 56 | 48.5 | G1 1/2 | 44 | 30 | 42 | 99.5 | + 0.1 | 96.5 | 79.5 | 31 | 22 | 16 | 7 | + 0.5 | 48 | 0.1 |
Notice:
Plug screws, separate order, see "Accessories"
Oiling of plug screws prior to installation is recommended.
Installation bore: Angle valve – plug screw according to RN 143.28 – up to 315 bar
Dimensions in mm
1) | Dimensions for countersinking the screw head. For lower installation of the installation kit, dimension T7 has to be extended accordingly. |
2) | Depth of fit |
3) | Metric ISO fine thread according to DIN 13 |
1 |
Range for outlet bore |
NG |
pN |
ØD1 |
ØD2H8 |
D3 |
ØD4H8 |
ØD5 |
ØD6H7 |
T1 |
T2 |
T3 |
T4 |
T5 |
T6 |
T7 |
T8 |
X |
||||
bar |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
||
25 | 315 | 56 | + 0.5 | 44 | M42 x 1,5 | 38 | 25 | 36 | 106.5 | + 0.1 | 104 | 88.5 | 45 | 39 | 33 | 5 | + 0.5 | 12 | + 0.2 | 43 |
30 | 315 | 62 | + 0.5 | 50 | M48 x 1,5 | 44 | 30 | 42 | 115.5 | + 0.1 | 112.5 | 95.5 | 48 | 39 | 33 | 5 | + 0.5 | 12 | + 0.2 | 48 |
Notice:
Plug screws, separate order, see "Accessories"
To be replaced in case of maintenance.
Installation bore: Angle valve – plug screw according to RN 143.28 – up to 420 bar
Dimensions in mm
1) | Dimensions for countersinking the screw head. For lower installation of the installation kit, dimension T7 has to be extended accordingly. |
2) | Depth of fit |
3) | Metric ISO fine thread according to DIN 13 |
1 |
Range for outlet bore |
NG |
pN |
ØD1 |
ØD2H8 |
D3 |
ØD4H8 |
ØD5 |
ØD6H7 |
ØD7 |
ØD8 |
T1 |
T2 |
T3 |
T4 |
T5 |
T6 |
T7 |
T8 |
X |
||||
bar |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
||
25 | 420 | 51 | + 0.5 | 44 | M42 x 2 | 38 | 25 | 36 | 37.58 | 35.58 | 101.5 | + 0.1 | 100 | 83.5 | 40 | 34 | 27 | 6 | + 0.5 | 7.8 | + 0.2 | 43 |
30 | 420 | 61 | + 0.5 | 50 | M48 x 2 | 44 | 30 | 42 | 43.58 | 41.58 | 110.5 | + 0.1 | 108.5 | 90.5 | 43 | 34 | 27 | 6 | + 0.5 | 7.8 | + 0.2 | 48 |
Notice:
Plug screws, separate order, see "Accessories" Oiling of plug screws prior to installation is recommended. From an operating pressure larger 350 bar, the plug screw has to be glued by means of Loctite 243 over the complete thread circumference.Installation bore: Straight-through valve
Dimensions in mm
NG |
ØD1H7 |
ØD3H8 |
D4 1) |
ØD5 |
D4 2) |
ØD5 |
ØD6 |
T1 |
T2 3) |
T3 |
T4 3) |
T5 |
T6 |
Z |
Poppet stroke |
|||
mm |
mm |
mm 1) |
mm |
mm 2) |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
|||
6 | 10 | 11 | G1/4 | 13.6 | ± 0.1 | M14 x 1,5 | 14.4 | ± 0.1 | 25 | 29.8 | - 0.1 | 27.8 | 21.8 | 19 | 12 | 16 | 0.1 | 4 |
8 | 13 | 14 | G3/8 | 17.1 | ± 0.1 | M18 x 1,5 | 18.4 | ± 0.1 | 28 | 32.8 | - 0.1 | 30.8 | 22.8 | 18 | 12 | 16 | 0.1 | 4 |
10 | 17 | 18 | G1/2 | 21.4 | ± 0.1 | M22 x 1.5 | 22.4 | ± 0.1 | 34 | 38.8 | - 0.1 | 36.8 | 28.8 | 21 | 14 | 19 | 0.1 | 4 |
15 | 22 | 24 | G3/4 | 26.8 | ± 0.1 | M27 x 2 | 27.4 | ± 0.1 | 42 | 48.4 | - 0.1 | 46.4 | 36.4 | 27 | 16 | 21 | 0.2 | 5 |
20 | 28 | 30 | G1 | 33.8 | ± 0.1 | M33 x 2 | 33.5 | ± 0.1 | 47 | 59 | - 0.1 | 57 | 44 | 29 | 18 | 24 | 0.2 | 5 |
25 | 36 | 38 | G1 1/4 | 42.5 | ± 0.1 | M42 x 2 | 42.5 | ± 0.1 | 58 | 73 | - 0.1 | 71 | 55 | 39 | 20 | 26 | 0.2 | 7 |
30 | 42 | 44 | G1 1/2 | 48.5 | ± 0.1 | M48 x 2 | 48.5 | ± 0.1 | 65 | 83 | - 0.1 | 81 | 63 | 42 | 22 | 28 | 0.2 | 7 |
1) | Pipe thread "G" according to ISO 228/1 |
2) | Metric ISO fine thread according to DIN 13 |
3) | Depth of fit |
Plug screw according to ZN 10001
Size |
Seal material |
Designation |
Material number |
Tightening torques MA ±10 % |
Buy |
Plug screw according to ZN 10001
Size |
Seal material |
Designation |
Material number |
Tightening torques MA ±10 % |
Buy |
Nm |
|||||
8 | NBR | ZN10001-G3/8A-N-ST | R913011602 | 55 | eShop |
FKM | ZN10001-G3/8A-F-ST | R913011610 | eShop | ||
10 | NBR | ZN10001-G1/2A-N-ST | R913011603 | 80 | eShop |
FKM | ZN10001-G1/2A-F-ST | R913011611 | eShop | ||
15 | NBR | ZN10001-G3/4A-N-ST | R913011604 | 135 | eShop |
FKM | ZN10001-G1 1/2A-F-ST | R913011612 | eShop | ||
20 | NBR | ZN10001-G1A-N-ST | R913011605 | 225 | eShop |
FKM | ZN10001-G1A-F-ST | R913011613 | eShop | ||
25 | NBR | ZN10001-G1 1/4A-N-ST | R913011606 | 360 | eShop |
FKM | ZN10001-G1 1/4A-F-ST | R913011614 | eShop | ||
30 | NBR | ZN10001-G1 1/2A-N-ST | R913011607 | 400 | eShop |
FKM | ZN10001-G1 1/2A-F-ST | R913011615 | eShop |
Plug screw according to RN 143.28 – up to 315 bar
Size |
Seal material |
Designation |
Material number |
Tightening torques MA ±10 % |
Buy |
Nm |
|||||
25 | NBR | M42X1,5-ST/320/NBR | R900323609 | 300 | eShop |
FKM | M42X1,5-ST/320/FKM | R900301957 | eShop | ||
30 | NBR | M48X1,5-ST/320/NBR | R900323610 | 325 | eShop |
FKM | M48X1,5-ST/320/FKM | R900301958 | eShop |
Plug screw according to RN 143.28 – up to 420 bar
Size |
Seal material |
Designation |
Material number |
Tightening torques MA ±10 % |
Buy |
Nm |
|||||
25 | NBR | M42X2-ST-PRECOTE85/630/NBR | R901183335 | 300 | eShop |
FKM | M42X2-ST-PRECOTE85/630/FKM | R901253503 | eShop | ||
30 | NBR | M48X2-ST-PRECOTE85/630/NBR | R901183336 | 325 | eShop |
FKM | M48X2-ST-PRECOTE85/630/FKM | R901253504 | eShop |
Related Products
R900424267
$516.00 USD
R900437466
$326.00 USD
R900334105
$602.00 USD
R900442490
$481.00 USD
R900976452
$927.00 USD