$191.59 USD
More are expected on January 30, 2025
Status: This product is temporarily out of stock.
Qty: Delivered as early as January 30, 2025 when ordered in
$191.59 USD
Status: This product is temporarily out of stock.
Qty: Delivered as early as January 30, 2025 when ordered in
Cable diameter D tolerance | |
Cable diameter D | 3.2 |
Bending cycles footnote | Technical data only for the cast-on connection line at the sensor. Even more performance, e.g. extension cables are offered for use in an energy chain. |
Connection type | Cable 10.0 m, 3-pin |
Galvanized connection ends | ✓ |
Permissible ambient temperature | -40 °C ... +85 °C |
Compatible | MKK/MKR-040 |
Electrical accessories for linear axes | Magnetic sensors |
Cable cross-section | 3x0,14 |
Static bending radius | ‒ |
Dynamic bending radius | ‒ |
Torsion-resistant footnote | Technical data only for the cast-on connection line at the sensor. Even more performance, e.g. extension cables are offered for use in an energy chain. |
Activation point (dimension x) | 13.65 |
Torsion-resistant | ‒ |
Operating voltage | 3.8 ... 30 |
Weld spark-resistant footnote | Technical data only for the cast-on connection line at the sensor. Even more performance, e.g. extension cables are offered for use in an energy chain. |
Weld spark-resistant | ‒ |
Short-circuit protection | ‒ |
Suitable for drag chains | nein |
Suitable for drag chains footnote | Technical data only for the cast-on connection line at the sensor. Even more performance, e.g. extension cables are offered for use in an energy chain. |
Load current | |
Switching function version | Hall, PNP/NC |
Productgroup ID | 17 |
MTTFd (per EN ISO 13849-1 ) | ‒ |
Permissible ambient temperature (max) | |
Bending cycles | ‒ |
Dynamic bending radius footnote | Technical data only for the cast-on connection line at the sensor. Even more performance, e.g. extension cables are offered for use in an energy chain. |
Permissible ambient temperature (min) | |
Switching frequency | 2.5 |
Protection class | IP66 |
Max. permissible approach speed | 2 |
Reverse polarity protection | ‒ |
Weight | 0.01 |
Certifications and approvals | ‒ |
Footnote cable cross-section | Technical data only for the cast-on connection line at the sensor. Even more performance, e.g. extension cables are offered for use in an energy chain. |
Switch-on suppression | no |
Functional principle | magnetic |
Use | Limit switch |
Pulse extension | ‒ |
Function indicator | no |
Part number |
R347600903 | R347601003 | R347601203 | R347601303 | R347601403 | R913011323 | R913011324 | R347601903 | R347601803 | |
Functional principle |
Magnetic | |||||||||
Contact type |
Hall, PNP normally closed | REED, changeover | ||||||||
Operating voltage |
V DC |
≤ 30 | 3.8 ... 30 | ≤ 30 | 3.8 ... 30 | |||||
Current consumption |
mA |
≤ 10 | ||||||||
Output current |
mA |
≤ 20 | ||||||||
Switching voltage |
V DC |
≤ 100 | ||||||||
Switching current |
mA |
≤ 500 | ||||||||
Cable length |
mm |
2000 | ||||||||
Housing protection class |
IP66 | |||||||||
Load current |
mA |
500 | ≤ 20 | 500 | ≤ 20 | |||||
Switching function |
REED / changeover contact (NC: C+NC, NO: C+NO) | Hall PNP/normally closed (NC) | Hall, PNP/normally open (NO) | Hall, NPN/normally closed (NC) | Hall, NPN/normally open (NO) | REED / changeover contact (NC: C+NC, NO: C+NO) | Hall PNP/normally closed (NC) | |||
Connection type |
Line 2.0 m, 3-pin | |||||||||
Galvanized connection ends |
✔ | |||||||||
Function indication |
‒ | |||||||||
Short-circuit protection |
‒ | |||||||||
Reverse polarity protection |
‒ | |||||||||
Switch-on suppression |
‒ | |||||||||
Switching frequency |
kHz |
2.5 | ||||||||
Pulse delay (Off delay) |
‒ | |||||||||
Maximum permissible starting speed |
m/s |
2 | ||||||||
Suitable for flexing installation 1) |
‒ | |||||||||
Can withstand torsion 1) |
‒ | |||||||||
Weld spark resistant 1) |
‒ | |||||||||
Cable cross-section 1) |
mm2 |
3x0,14 | ||||||||
Cable diameter D 1) |
3.2 mm ±0.2 | |||||||||
Bending radius, stationary 1) |
‒ | |||||||||
Bending radius, flexing 1) |
‒ | |||||||||
Bending cycles 1) |
‒ | |||||||||
Maximum permissible travel speed 1) |
‒ | |||||||||
Maximum permissible acceleration 1) |
‒ | |||||||||
Permissible ambient temperature (min ... max) |
-40 °C ... +85 °C | |||||||||
Protection type |
IP66 | |||||||||
MTTFd (as per EN ISO 13849-1 ) |
‒ | |||||||||
Certifications and approvals |
‒ |
1) | Technical data only for the cast-on connection line at the sensor. Even more performance, e.g. extension cables are offered for use in a cable management chain. |
Attention: R347601803 has 2 switching points.
1) | Hall sensor |
2) | Reed sensor |
3) | White: +3.8 ... 30 VDC |
4) | Green: Output |
5) | Brown: 0 V ground |
6) | Brown |
7) | White |
8) | Green |
1) | Cable length 10 m |
2) | Activation point |
3) | Active surface |
4) | Set screw for retention |
Part number |
Activation point (dimension "X") |
mm |
|
R347600903 | 9 |
R347601003 | 13.65 |
R347601203 | |
R347601303 | |
R347601403 | |
R913011323 | 9 |
R913011324 | 13.65 |
R347601903 | - |
R347601803 |
No certificate for import into
the Chinese market is necessary for these products.
$369.04 USD
$1,317.45 USD
$1,479.01 USD
$7,665.00 USD
$2,803.00 USD
Contact us below: