PUMP CONTROL SYSTEM SYDFE1-2X/028R-PPA12N00-0000-B0X0XXX
Manufacturer: Bosch Rexroth
Material #: R978917113
Model : SYDFE1-2X/028R-PPA12N00-0000-B0X0XXX
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Bosch Rexroth directly.***
The Bosch Rexroth SYDFE1-2X/028R-PPA12N00-0000-B0X0XXX (R978917113) is an advanced hydraulic pump system designed for precision control in fluid power applications. This particular model boasts a swash plate design, enabling variable displacement capabilities, and is suitable for systems requiring a maximum operating pressure of up to 280 bar. The unit's size and nominal pressure rating are tailored to deliver optimum performance within its specified range.
Equipped with external analog electronics, the pump facilitates swivel angle control, pressure regulation, and torque limitation functions. It also supports master-slave operation for complex system configurations. The SYDFE1-2X/028R-PPA12N00-0000-B0X0XXX features a clockwise rotation direction and can operate at speeds ranging from a minimum speed to its maximum rated speed.
The hydraulic pump system includes several key components: a pilot valve with an inductive position transducer for accurate valve positioning, an actuating piston, counter piston, drive shaft, and connection flange. Additionally, it incorporates spring mechanisms and a swivel angle position sensor to ensure precise control of the pump's displacement.
For electrical connections, the unit utilizes valve connectors as well as SWA connectors to integrate seamlessly into various hydraulic circuits. Its supply voltage requirement is 24 VDC without the need for throughdrive capabilities. The pump is designed with FKM seals and can handle HLP hydraulic fluid effectively.
With its robust design and precise control features, the Bosch Rexroth SYDFE1-2X/028R-PPA12N00-0000-B0X0XXX offers reliable performance for demanding hydraulic applications where analog connectivity and external control electronics are necessary for operation.
$7,407.00 USD
More are expected on April 28, 2025
Status: This product is temporarily out of stock.
Qty: Delivered as early as April 28, 2025 when ordered in
This product is eligible for factory repair.
Pump A10VSO BR31 with external analog electronics
Pump system, maximum operating pressure 280 bar, size 28, functionality: Swivel angle, pressure control, master/slave
Unpacked Weight: 22.3 kg
A SYDFE1-2X control system is used for the electro-hydraulic control of swivel angle, pressure and power (partially optional, see type key pilot control and preload valve and ordering code) of an axial piston variable displacement pump.
The control system consists of the following components: Axial piston variable displacement pump A10VSO.../31 VT-DFP-.2X proportional valve as pilot valve including inductive position transducer for valve position sensing. External control electronics VT 5041-3X for realizing all electric functions necessary for the SYDFE1-2X (separate order) Position transducer for sensing the swivel angle Pressure transducer with suitable signal level and dynamics (optionally HM 20, otherwise separate order) Preload valve with integrated pressure relief function SYDZ (optional)
1 |
Swash plate |
2 |
Pilot valve |
3 |
Counter piston |
4 |
Actuating piston |
5 |
Spring |
6 |
Inductive position transducer for valve position |
7 |
Swivel angle position sensor |
8 |
Proportional solenoid |
9 |
Valve spool |
10 |
Spring |
15 |
Drive shaft |
16 |
Connection flange |
17 |
Subplate, optionally with through-drive |
Own supply |
Component series 2X |
28 cm³ |
Nominal pressure 280 bar |
Communication: analog |
Maximum operating pressure 280 bar |
External control electronics |
Function: Pressure, swivel angle control, torque limitation, master-slave |
Size 18 … 100 |
With axial piston variable displacement pump A10VSO.../31 |
Data Sheet | Download Data Sheet |
Manual | Download Manual |
Manual | Download Manual |
Manual | Download Manual |
Max. pressure | 280 |
Shaft end | Fitting key shaft |
Electrical connection description | Valve connector, valve position transducer connector, SWA connector |
Size | 28 |
Speed min. | 250 |
Productgroup ID | 9,10,11,12,13,14 |
Speed max. | 3000 |
Mounting flange | ISO 2-hole |
Max. flow | 84 |
Displacement type | variable |
Direction of rotation | clockwise rotation |
Supply voltage | 24 VDC |
Through-drive | without |
Weight | 22.3 |
Seals | FKM |
Connectivity | Analog |
Hydraulic fluid | HLP |
Hydraulic fluid | HLP |
01 |
02 |
03 |
04 |
05 |
06 |
07 |
08 |
09 |
10 |
11 |
12 |
13 |
14 |
|||||
SYDFE1-2X |
/ |
– |
P |
12 |
– |
– |
0 |
XX0XX |
– |
* |
Pump of the SYDFE control system |
|||||||||
Series |
|||||||||
01 |
Control system for external analog electronics (separate order) |
SYDFE1-2X |
|||||||
Pump combinations (see order example) |
SY2DFE.-2X, |
||||||||
Size |
018 |
028 |
045 |
071 |
100 |
140 |
|||
02 |
Displacement cm³ |
18 |
28 |
45 |
71 |
100 |
140 |
||
Direction of rotation looking at the drive shaft |
|||||||||
03 |
Right |
● |
● |
● |
● |
● |
● |
R |
|
Left |
● |
● |
● |
● |
● |
● |
L |
||
Hydraulic fluid |
|||||||||
04 |
Mineral oil according to DIN 51524 (HL/HLP) |
● |
● |
● |
● |
● |
● |
P |
|
Drive shaft variant |
|||||||||
05 |
Cylindrical with fitting key DIN 6885 (not in connection with through-drive) |
Ø18 |
Ø22 |
Ø25 |
Ø32 |
Ø40 |
Ø45 |
P |
|
Splined shaft profile SAE J 744 1) |
3/4" |
– |
– |
– |
1 1/2" |
1 3/4" |
S |
||
Splined shaft profile SAE J 744 (higher torque) |
– |
7/8" |
1" |
1 1/4" |
– |
– |
R |
||
Connection flange (centering in mm) |
Ø18 |
Ø22 |
Ø25 |
Ø32 |
Ø40 |
Ø45 |
|||
06 |
ISO 2-hole |
80 |
100 |
100 |
125 |
125 |
– |
A |
|
ISO 4-hole |
– |
– |
– |
– |
– |
180 |
B |
||
SAE 2-hole |
82,55 |
101,6 |
101,6 |
127 |
127 |
– |
C |
||
SAE 4-hole |
– |
– |
– |
– |
– |
152,4 |
D |
||
Port for working lines pressure port B and suction port S |
|||||||||
07 |
SAE, laterally opposite, mounting thread metric |
● |
● |
● |
● |
● |
● |
12 |
|
Through-drive (All through-drives with single pumps come without a hub and are operationally safe, provided with an end cover) |
|||||||||
08 |
Without through-drive |
● |
● |
● |
● |
● |
● |
N00 |
|
Centering |
Attachment pump (examples) 2) |
||||||||
ISO Ø100 mm |
A10VSO..31 NG28/45 |
– |
● |
● |
● |
● |
● |
KD3 |
|
ISO Ø125 mm |
A10VSO..31 NG71/100 |
– |
– |
– |
● |
● |
● |
KD5 |
|
ISO Ø180 mm |
A10VSO..31 NG140 |
– |
– |
– |
– |
– |
● |
KD7 |
|
SAE Ø82.55 mm |
A10VSO..31 NG18, PGF2, PGH2, PGH3, AZPF |
● |
● |
● |
● |
● |
● |
KC1 |
|
SAE Ø101.6 mm |
PGH4, 1PF2G3, PGF3 |
– |
● |
● |
● |
● |
● |
KC3 |
|
SAE Ø127 mm |
PGH5 |
– |
– |
– |
● |
● |
● |
KC5 |
|
SAE Ø152.4 mm |
A10VO140 |
– |
– |
– |
– |
– |
● |
KC6 |
|
Base pump variant |
|||||||||
09 |
Standard (internal pilot oil) |
● |
● |
● |
● |
● |
● |
● |
0000 |
External supply |
– |
● |
● |
● |
● |
● |
– |
0479 |
|
External supply + regenerative operation |
– |
– |
– |
– |
● |
● |
● |
0487 |
|
Pilot and preload valve of the SYDFE1 control system |
|||||||||
Spool design |
|||||||||
10 |
Standard (NG28 ... NG140) |
A |
|||||||
2-groove spool (NG18 ... NG140, only for replacement requirement) |
B |
||||||||
4-groove spool (NG18) |
C |
||||||||
Installation orientation, solenoid |
|||||||||
11 |
Mating connector is orientated radially to the pump axis |
0 |
|||||||
12 |
Features currently not used |
X0XX |
|||||||
Preload valve with integrated pressure limitation |
|||||||||
13 |
Pressure limitation 200 bar (tolerance ± 8 bar) |
1 |
|||||||
Pressure limitation 250 bar (tolerance ± 10 bar) |
2 |
||||||||
Pressure limitation 300 bar (tolerance ± 12 bar) |
3 |
||||||||
Without preload valve |
X |
||||||||
14 |
Further details in the plain text e. g. SO variant |
* |
1) | ANSI B92.1a-1976, 30° pressure angle, flat root, side fit, tolerance class 5. |
2) | Also observe the conditions for the attachment pumps. |
● |
available |
- |
not available |
Ordering code pump combination SYHDFE1-2X
01 |
02 |
03 |
04 |
05 |
||||
SY2HDFE1-2X |
/ |
– |
/ |
+ |
01 |
2-fold pump |
SY2HDFE1-2X |
02 |
Size of the main pump 1) |
|
03 |
Size of the attachment pump or pump abbreviation if the attachment pump is not SYHDFE (e.g. PGF) 1) |
|
04 |
Material number without "R9" for the main pump or type designation if material number is not known |
|
05 |
Material number without "R9" for the attachment pump or type designation if material number is not known |
1) | Detailed information see type key |
01 |
02 |
03 |
04 |
|||
SY3HDFE1-2X |
/ |
+ |
+ |
01 |
3-fold pump |
SY3HDFE1-2X |
02 |
Material number without "R9" for the main pump or type designation if material number is not known |
|
03 |
Material number without "R9" for the attachment pump or type designation if material number is not known |
|
04 |
Material number without "R9" for the attachment pump or type designation if material number is not known |
Example of name plate of a pump combination
For enquiries regarding the control system, material number, production order number, serial number, and date of production are necessary.
Accessories |
Material number |
Data sheet |
External control electronics VT 5041-3X/1 without power limitation, without swivel angle display |
R901236404 |
30242 |
External control electronics VT 5041-3X/2 without power limitation, with swivel angle display |
R901263598 |
30242 |
External control electronics VT 5041-3X/3 with power limitation, with swivel angle display |
R901196678 |
30242 |
Mating connector for solenoid plug |
R901017011 |
08006 |
Mating connector for position transducer of valve |
R900023126 |
08006 |
Mating connector for position transducer of pump |
R900013674 |
|
Pressure transducer HM 20-2X, measurement range 315 bar (4 ... 20 mA) |
R901342029 |
30272 |
Pressure transducer HM 20-2X, measurement range 315 bar (0.1 ... 10 V) |
R901342030 |
30272 |
Card holder VT 3002-1-2X/32D |
R900020153 |
29928 |
Compact power supply unit VT-NE32-1X |
R900080049 |
29929 |
More accessories |
||
Accessories for through-drives |
See Accessories |
|
Torsionally flexible couplings for attachment to a standard electric motor |
See Accessories |
mechanic and hydraulic
Size |
18 | 28 | 45 | 71 | 100 | 140 | ||||
Displacement |
Vg max |
cm³ |
18 | 28 | 45 | 71 | 100 | 140 | ||
Speed 1) |
maximum at Vg max |
nnom |
rpm |
3300 | 3000 | 2600 | 2200 | 2000 | 1800 | |
maximum at Vg < Vg max |
nmax zul |
rpm |
3900 | 3600 | 3100 | 2600 | 2400 | 2100 | ||
Minimum speed |
nmin |
rpm |
50 | |||||||
Max. flow (displacement) |
at nnom and Vg max |
qV max |
l/min |
59.4 | 84 | 117 | 156 | 200 | 252 | |
with nE = 1500 rpm and Vg max |
qvE max |
l/min |
27 | 42 | 68 | 107 | 150 | 210 | ||
Max. power (Δp = 280 bar) |
at nnom and Vg max |
P max |
kW |
27.7 | 39 | 55 | 73 | 93 | 118 | |
with nE = 1500 rpm and Vg max |
PE max |
kW |
12.6 | 20 | 32 | 50 | 70 | 98 | ||
Max. torque (Δp = 280 bar) |
Tmax |
Nm |
80.1 | 125 | 200 | 316 | 445 | 623 | ||
Maximum permissible drive torque |
Fitting key |
Ttotal |
Nm |
88 | 137 | 200 | 439 | 857 | 1206 | |
Splined shaft S overall torque |
Ttotal |
Nm |
124 | - | 1104 | 1620 | ||||
Max. admissible through-drive torque |
TD |
Nm |
108 | - | 778 | 1266 | ||||
Splined shaft R overall torque |
Ttotal |
Nm |
- | 225 | 400 | 644 | - | |||
Max. admissible through-drive torque |
TD |
Nm |
- | 176 | 365 | 548 | - | |||
Drive shaft load |
max. admissible axial force |
Fax max |
N |
700 | 1000 | 1500 | 2400 | 4000 | 4800 | |
max. admissible radial force |
Fq |
N 2) |
350 | 1200 | 1500 | 1900 | 2300 | 2800 | ||
Mass |
Pump without through-drive incl. pilot valve |
m |
kg |
14 | 17 | 23 | 35 | 47 | 62 | |
in addition, preload valve |
m |
kg |
3.3 | 6.3 | ||||||
in addition, in case of external supply |
m |
kg |
2 | |||||||
Moment of inertia around drive axis |
kg·m² |
0.0009 | 0.0017 | 0.0033 | 0.0083 | 0.0167 | 0.0242 | |||
Filling quantity of the housing |
l |
0.4 | 0.7 | 1 | 1.6 | 2.2 | 3 | |||
Maximum admissible operating pressure |
pmax |
bar |
280 3) | 280 | ||||||
Operating pressure, min. (without load) |
with preload valve |
pmin |
bar |
≥ 1 | ||||||
without preload valve |
pmin |
bar |
≥ 20 | |||||||
in case of external supply (20 bar) 4) |
pmin |
bar |
> 10 | |||||||
Admissible inlet pressure |
p |
bar |
0.8 ... 10 | |||||||
Hydraulic fluid |
Mineral oil (HL, HLP) to DIN 51524 | |||||||||
Hydraulic fluid temperature range |
ϑ |
°C |
-20 … +70 | |||||||
Maximum admissible degree of contamination of the hydraulic fluid according to ISO 4406 |
Class 18/16/13 (for particle size ≤ 4/6/14 μm) |
1) | The values are applicable at an absolute pressure of 1 bar at the suction opening S. With a reduction of the displacement or an increase in the inlet pressure, the speed can be increased according to the following characteristic curve. With a reduced inlet pressure, the speed is to be reduced. |
2) | In case of higher radial forces, please consult us |
3) | In case of higher pressures, please consult us |
4) | In continuous operation; in case of operation below 10 bar, observe the notes |
Notice:
For information on the environment simulation testing for the areas of EMC (electro-magnetic compatibility), climate and mechanical load, see data sheet 30030-U.
Control loop quality
Notes:
The specified values are only valid when using the system-related components specified in this data sheet. At pressures < 20 bar, higher tolerances have to be anticipated due to lower actuating forces.
Swivel angle control |
Pressure control 1) |
|
Linearity tolerance |
≤ 1.0 % |
≤ 1.5 % (≤ 1.0 %) |
Temperature error |
≤ 0.5 % / 10 K |
≤ 0.5 % / 10 K |
Hysteresis |
≤ 0.2 % |
≤ 0.2 % |
Repetition accuracy |
≤ 0.2 % |
≤ 0.2 % |
1) | Without considering the pump pulsation. |
For applications outside these parameters, please consult us!
Transition function with pressure command value step with spool design "A"
The specified curve shapes and control times refer to a drive speed of 1500 rpm and are only reached with an optimization of the pressure controller.
T 95% in ms with a connected hydraulic fluid volume (lines and actuators)
Hydraulic fluid volume in l |
T95% in ms |
< 5 |
150 |
5 ... 10 |
200 |
15 ... 15 |
250 |
Transition function with swivel angle command value step with spool design "A"
Size 18, 28, 45, 71 p = 20 bar
Size 18, 28, 45, 71 p = 50 bar
Size 100 p = 50 bar
Size 140 p = 50 bar
For pressures up to 40 bar, the values of the response times are greater.
Valve switch-off in case of error |
Jumper |
J1 |
|
Active |
OFF * |
Inactive |
ON |
* compatible with VT 5041-2X |
Schematic diagram: Actuating system supplied internally
1) | Separate order |
2) | Optional |
Schematic diagram: Actuating system supplied externally
The representation shows an example with integrated electronics. The external supply of the actuating system is also possible with external electronics.
1) | The use of an anti-cavitation valve (check valve with 0.2 bar spring) is essential in order to prevent dry-running in the error case. |
2) |
Pressure transducer |
Mounting options |
Comment |
HM 20-2X/315-F-C13-0.5 (cable version) |
P |
Only in connection with actual pressure value input "F" |
|
HM 20-2X/...-.-K35 (connector version) |
P1 |
Preferably close to the actuator |
3) Maximum pressure limitation must be provided by the customer! | |
4) Observe upper limit for external pilot oil pressure! (see operating instructions), recommendation: 20 bar absolute. |
Important notes on external supply:
In the case of an actuating system with external supply, the pump adjustment will - in case of voltage failure - not switch to zero stroke but to the negative stop (displacement of 100 % flow from the system to the tank). With an active fault message, it is imperative that the machine control reacts (e. g. switching off the drive motor of the pump, interrupting the external supply of the actuating system). The command values for pressure and flow must always be greater than zero (pcommand ≥ 3 bar, αcommand ≥ 5 %) as due to drift or tolerances, there is no exact "zero" pressure or "zero" swivel angle. Under unfavorable conditions, smaller command value presettings can lead to cavitation. The actual pressure value must not be less than 10 bar for more than 10 minutes (lubrication).
Leakage compensation |
Jumper |
|
J6 |
J7 |
|
Off |
OFF |
OFF |
4 % |
OFF |
ON |
6 % |
ON |
OFF |
10 % |
ON |
ON |
Valve command value monitoring |
Jumper |
J9 |
|
On |
ON |
Off * |
OFF |
Diagnosis LEDs |
For a description, see block diagram and the operating instructions 30011-B |
Regenerative operation |
Jumper |
|
J3 |
J5 |
|
On |
ON |
OFF |
Off |
OFF |
ON |
Function pin 18a ** |
Jumper |
J4 |
|
Pressure control |
OFF |
Master/slave |
ON |
** Only for versions without power limitation (VT 5041-3X/1-0 and VT 5041-3X/2-0) |
Selection for analog input at pin 18c |
Jumper |
J2 |
|
Bridge |
|
Actual master swivel angle value |
1-2 |
external power limitation |
2-3 |
Pressure controller p amplification |
Switch S3 |
Jumper |
|
.7 |
.8 |
J11 |
|
8,0 |
OFF |
OFF |
OFF |
4,8 |
OFF |
ON |
OFF |
4,0 |
OFF |
OFF |
ON |
3,0 |
OFF |
ON |
ON |
2,4 |
ON |
OFF |
ON |
2,0 |
ON |
ON |
ON |
Volume adjustment of pressure controller |
|||
Input switch TD = OFF |
Switch S3 |
||
.1 |
.2 |
.3 |
|
≤ 5,0 l |
OFF |
OFF |
OFF |
7,5 l |
OFF |
ON |
OFF |
10,0 l |
ON |
ON |
OFF |
15,0 l |
ON |
OFF |
ON |
20,0 l |
OFF |
ON |
ON |
25,0 l |
ON |
ON |
ON |
Input switch TD = ON |
Switch S3 |
||
.4 |
.5 |
.6 |
|
12,5 l |
OFF |
OFF |
OFF |
30,0 l |
OFF |
ON |
OFF |
45 l |
ON |
ON |
OFF |
60 l |
ON |
OFF |
ON |
75 l |
OFF |
ON |
ON |
90 l |
ON |
ON |
ON |
Actual pressure value amplification |
Jumper |
J10 |
|
1-fold |
OFF |
2-fold |
ON |
Signal adjustment of actual pressure value |
Switch S2 |
||||||||
.1 |
.2 |
.3 |
.4 |
.5 |
.6 |
.7 |
.8 |
||
V |
0...10 V |
OFF |
OFF |
OFF |
OFF |
OFF |
OFF |
ON |
ON |
E |
1...10 V |
OFF |
OFF |
OFF |
OFF |
ON |
OFF |
OFF |
ON |
D |
0...5 V |
OFF |
OFF |
ON |
ON |
OFF |
OFF |
ON |
ON |
F |
0,5...5 V |
OFF |
OFF |
ON |
ON |
ON |
OFF |
OFF |
ON |
B |
0...20 mA |
ON |
ON |
OFF |
OFF |
OFF |
OFF |
ON |
ON |
C |
4...20 mA |
ON |
ON |
OFF |
OFF |
ON |
ON |
OFF |
OFF |
Explanations: |
|
ON |
Bridge closed |
OFF |
Bridge open |
Factory setting |
For the meaning of the measuring sockets, display and adjustment elements (potentiometer) on the front plate, see front plate.
VT 5041-3X/1-0
LED displays |
|
Ub (green) |
Supply voltage available |
En. (green) |
Enable available |
Err. (red) |
Fault/collective error |
p-control (yellow) |
Pressure control enabled |
Swivel angle control enabled |
|
FE1 contr. (yellow) |
Pressure controller disabled |
Adjustment elements (potentiometer) |
|
R1 |
Zero point of actual pressure value |
R2 |
Actual pressure value amplification |
R6 |
Zero point of actual valve value |
R8 |
Zero point of actual swivel angle value |
R9 |
Amplification of actual swivel angle value |
Measuring sockets (Ri = 2 kΩ) |
|
1 |
Pressure command value 0…+10 V |
2 |
Actual pressure value 0…+10 V |
3 |
Swivel angle command value ±10 V |
4 |
Swivel angle command value |
5 |
Valve command value ±10 V |
6 |
Actual valve value ±10 V |
7 |
Active swivel angle command value ±10 V |
8 |
Power limit 0…+10 V |
⊥ |
Reference for measured values |
⊥ |
Reference for measured values |
Display (measuring instrument) |
|
Display of actual swivel angle value in % |
VT 5041-3X/2-0
LED displays |
|
Ub (green) |
Supply voltage available |
En. (green) |
Enable available |
Err. (red) |
Fault/collective error |
p-control (yellow) |
Pressure control enabled |
Swivel angle control enabled |
|
FE1 contr. (yellow) |
Pressure controller disabled |
Adjustment elements (potentiometer) |
|
R1 |
Zero point of actual pressure value |
R2 |
Actual pressure value amplification |
R6 |
Zero point of actual valve value |
R8 |
Zero point of actual swivel angle value |
R9 |
Amplification of actual swivel angle value |
Measuring sockets (Ri = 2 kΩ) |
|
1 |
Pressure command value 0…+10 V |
2 |
Actual pressure value 0…+10 V |
3 |
Swivel angle command value ±10 V |
4 |
Swivel angle command value |
5 |
Valve command value ±10 V |
6 |
Actual valve value ±10 V |
7 |
Active swivel angle command value ±10 V |
8 |
Power limit 0…+10 V |
⊥ |
Reference for measured values |
⊥ |
Reference for measured values |
Display (measuring instrument) |
|
Display of actual swivel angle value in % |
VT 5041-3X/3-0
LED displays |
|
Ub (green) |
Supply voltage available |
En. (green) |
Enable available |
Err. (red) |
Fault/collective error |
p-control (yellow) |
Pressure control enabled |
Swivel angle control enabled |
|
Power Limiter (yellow) |
Power limitation active |
Adjustment elements (potentiometer) |
|
R1 |
Zero point of actual pressure value |
R2 |
Actual pressure value amplification |
R3 |
Setting of the power limit |
R6 |
Zero point of actual valve value |
R8 |
Zero point of actual swivel angle value |
R9 |
Amplification of actual swivel angle value |
Measuring sockets (Ri = 2 kΩ) |
|
1 |
Pressure command value 0…+10 V |
2 |
Actual pressure value 0…+10 V |
3 |
Swivel angle command value ±10 V |
4 |
Swivel angle command value |
5 |
Valve command value ±10 V |
6 |
Actual valve value ±10 V |
7 |
Active swivel angle command value ±10 V |
8 |
Power limit 0…+10 V |
⊥ |
Reference for measured values |
⊥ |
Reference for measured values |
Display (measuring instrument) |
|
Display of actual swivel angle value in % |
Electrical properties of the SYDFE1 see VT 5041
The unit dimensions of the base pump (axial piston variable displacement pump A10VSO.../31) are contained in data sheet 92711.
Size 18 … 140
(Shaft design "S”; without through-drive “N00”)
Dimensions in mm
(representation Size 71)
Dimensions with base pump variant "0479" or "0487" |
|||||||||||
Size |
A1 |
A2 |
A3 |
A4 |
A5 |
A6 |
A6 I |
A6 II |
A7 I |
A7 II |
A7 III |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
|
18 | 98 | 110 | 161 | 158 | 63 | 178 | 63 | 115 | 196 | 125 | 100 |
28 | 106 | 110 | 171 | 158 | 63 | 195 | 80 | 115 | 206 | 135 | 115 |
45 | 112 | 110 | 181 | 158 | 63 | 205 | 90 | 115 | 216 | 145 | 125 |
71 | 124 | 110 | 195 | 158 | 63 | 254 | 104 | 150 | 230 | 159 | 150 |
100 | 129 | 110 | 200 | 158 | 63 | 247 | 100 | 147 | 235 | 164 | 150 |
140 | 140 | 110 | 213 | 143 | 78 | 257 | 110 | 147 | 248 | 182 | 150 |
Combination pumps
Attachment pump |
Main pump |
|||||||||||||||||||||||
A10VSO 18 |
A10VSO 28 |
A10VSO 45 |
A10VSO 71 |
A10VSO 100 |
A10VSO 140 |
|||||||||||||||||||
A1 |
A2 |
A3 |
A4 |
A1 |
A2 |
A3 |
A4 |
A1 |
A2 |
A3 |
A4 |
A1 |
A2 |
A3 |
A4 |
A1 |
A2 |
A3 |
A4 |
A1 |
A2 |
A3 |
A4 |
|
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
|
A10VSO 18 |
164 |
204 |
349 |
399 |
164 |
204 |
349 |
399 |
184 |
229 |
374 |
424 |
217 |
267 |
412 |
462 |
275 |
338 |
483 |
533 |
275 |
350 |
495 |
554 |
A10VSO 28 |
164 |
204 |
368.5 |
410 |
184 |
229 |
393.5 |
435 |
217 |
267 |
431.5 |
473 |
275 |
338 |
502.5 |
544 |
275 |
350 |
514 |
556 |
||||
A10VSO 45 |
184 |
229 |
413 |
453 |
217 |
267 |
451 |
491 |
275 |
338 |
522 |
562 |
275 |
350 |
534 |
574 |
||||||||
A10VSO 71 |
217 |
267 |
484 |
524 |
275 |
338 |
555 |
595 |
275 |
350 |
567 |
609 |
||||||||||||
A10VSO 100 |
275 |
338 |
613 |
664 |
275 |
350 |
625 |
679 |
||||||||||||||||
A10VSO 140 |
275 |
350 |
625 |
688 |
Ports
Size |
18 |
28 |
45 |
71 |
100 |
140 |
||
B: |
Working line (SAE J518) 1) |
|||||||
Size |
3/4" |
3/4" |
1" |
1" |
1 1/4" |
1 1/4" |
||
Mounting thread (DIN 13) |
M10 x 1.5; 17 deep |
M14 x 2; 19 deep |
||||||
Maximum pressure 2) |
bar |
350 |
||||||
S: |
Suction line (SAE J518) 1) |
|||||||
Size |
1" |
1 1/4" |
1 1/2" |
2" |
2 1/2" |
2 1/2" |
||
Mounting thread (DIN 13) |
M10 x 1.5; 17 deep |
M12 x 1.75; 20 deep |
M12 x 1.75; 17 deep |
|||||
Maximum pressure 2) |
bar |
10 |
1) | Dimensions according to SAE J518 only, metric mounting thread deviating from the standard. |
2) | Application-specific short-time pressure peaks may occur. Please observe when selecting measuring devices and fittings. Specified pressures are in bar absolute. |
Notes regarding size 71:
With pressure connection “B” of size 71, two SAE mounting connections rotated by 90° are available. SAE 1 1/4″ standard pressure series, 207 bar , for pressures up to 250 bar or SAE 1″ standard pressure series, 344 bar, for pressures up to 350 bar. For operating pressures exceeding 250 bar, the pressure flange SAE 1” must be used.Dimensions in mm
Hubs for through-drives
Hubs for the combination of single pumps or the combination of SYDFE with other pumps. Observe that the attachment pump has a splined shaft SAE J744 with the specified diameter.
The following conditions apply to the attachment pumps listed in the table:
SYDFE and A10VSO with shaft S or R Internal gear pump PGH with shaft R, flange U2, see data sheet 10223 Internal gear pump PGF3 with shaft J, flange U2, see data sheet 10213 External gear pump AZPF with shaft R, front cover R, see data sheet 10089Observe that the through-drive of the main pump and the flange of the attachment pump (see type key pump) are identical. Check in the current data sheet of the gear pump whether the shaft ends have the specified dimensions.
Main pump SYDFE or A10VSO... |
Attachment pump |
||||||
Size 18 |
Size 28 |
Size 45 |
Size 71 |
Size 100 |
Size 140 |
Ø shaft |
Pump type (examples) |
R902436099 |
R902436199 |
R902436100 |
R902436200 |
R902436201 |
R902436202 |
3/4" 19-4 (SAE A-B) |
SYDFE-2X, A10VSO..31 |
R902436098 |
R902436084 |
R902436083 |
R902436101 |
R902436102 |
7/8" 22-4 (SAE B) |
SYDFE-2X, A10VSO..31 |
|
R902436103 |
R902436104 |
R902436105 |
R902436204 |
1" 25-4 (SAE B-B) |
SYDFE-2X, A10VSO..31 |
||
R902436085 |
R902436105 |
R902436106 |
1 1/4" 32-4 (SAE C) |
SYDFE-2X, A10VSO..31 |
|||
R902436086 |
R910943555 |
1 1/2" 38-4 (SAE C-C) |
SYDFE-2X, A10VSO..31 |
||||
R910943565 |
R910932172 |
1 3/4" 44-4 (SAE D) |
SYDFE-2X, A10VSO..31 |
||||
R910943528 |
R910986299 |
R910943529 |
R91094345 |
R910943560 |
R910943551 |
5/8" 16-4 (SAE A) |
1PF2G2, PGF2, PGH2, PGH3, AZPF |
Through-drives
KD3
Flange ISO 100, 2-hole for the attachment of
SYDFE.-2X (size 28 and size 45, flange A) A10VSO..31 (size 28 and size 45, flange A, see data sheet 92711)
Sectional presentation with examples for hubs (order number for hubs see hubs for through-drives)
Dimensions in mm
Size |
A1 |
A2 |
A3 |
A4 |
A5 |
A6 |
mm |
mm |
mm |
mm |
mm |
||
28 | 204 | 41.7 | 17.8 | - | - | M12; 15 right through |
45 | 229 | 41.7 | 17.9 | 46.7 | 18.4 | M12; 14 right through |
71 | 267 | 44.1 | 20.3 | 49.1 | 20.8 | M12; 20 deep |
100 | 338 | 41 | 17.6 | 45.9 | 18.2 | M12; 20 deep |
140 | 350 | 41.1 | 18 | 45.9 | 18.3 | M12; 20 deep |
KD5
Flange ISO 125, 2-hole for the attachment of
SYDFE.-2X (size 71 and size 100, flange A) A10VSO..31 (size 71 and size 100, flange A, see data sheet 92711)
Sectional presentation with examples for hubs (order number for hubs see hubs for through-drives)
Dimensions in mm
Size |
A1 |
A2 |
A3 |
A4 |
A5 |
A6 |
mm |
mm |
mm |
mm |
mm |
||
71 | 267 | 58.6 | 21.8 | - | - | M16; 20 right through |
100 | 338 | 56.4 | 19.5 | 63.9 | 7.9 | M16; 20 deep |
140 | 350 | 55.4 | 17.4 | 73.3 | 7.9 | M16; 20 deep |
KD7
Flange ISO 180, 4-hole for the attachment of
SYDFE.-2X (NG140, flange B) A10VSO..31 (NG140, flange B, see data sheet 92711)
Sectional presentation with examples for hubs (order number for hubs see hubs for through-drives)
Dimensions in mm
Size |
A1 |
A2 |
A3 |
A5 |
mm |
mm |
mm |
||
140 | 350 | 75 | 8 | M16; 22 right through |
KC1
Flange SAE 82-2 (SAE A, 2-hole) for the attachment of
SYDFE.-2X (size 18, flange C) A10VSO..31 (size 18, flange C, see data sheet 92711) PGF2 (shaft J, flange U2, see data sheet 10213) PGH2 and PGH3 (shaft R, flange U2, see data sheet 10223) AZPF (shaft R, front cover R, see data sheet 10089)
Sectional presentation with examples for hubs (order number for hubs see hubs for through-drives)
Dimensions in mm
Size |
A1 |
A2 |
A3 |
A4 |
mm |
mm |
mm |
||
18 | 182 | 40 | 43 | M10; 14.5 deep |
28 | 204 | 39 | 47 | M10; 16 deep |
45 | 229 | 40.5 | 53 | M10; 16 deep |
71 | 267 | 40 | 61 | M10; 20 deep |
100 | 338 | 40 | 65 | M10; 20 deep |
140 | 350 | 41 | 77 | M10; 17 deep |
KC3
Flange SAE 101-2 (SAE B, 2-hole) for the attachment of
SYDFE.-2X (size 28 and size 45, flange C) A10VO..31 (size 28 and size 45, flange C, see data sheet 92701) PGF3 (shaft J, flange U2, see data sheet 10213) PGH4 (shaft R, flange U2, see data sheet 10223)
Sectional presentation with examples for hubs (order number for hubs see hubs for through-drives)
Dimensions in mm
Size |
A1 |
A2 |
A3 |
A4 |
A5 |
A6 |
A7 |
mm |
mm |
mm |
mm |
mm |
mm |
||
28 | 204 | 43 | 16.5 | 47 | - | - | M12; 15 deep |
45 | 229 | 42 | 16.5 | 53 | 18.4 | 46.7 | M12; 18 deep |
71 | 267 | 43 | 16.5 | 61 | 20.8 | 49.1 | M12; 20 deep |
100 | 338 | 41 | 16.5 | 65 | 10.5 | 65 | M12; 20 deep |
140 | 350 | 44 | 16.5 | 77 | 18.3 | 45.9 | M12; 20 deep |
KC5
Flange SAE 127-2 (SAE C, 2-hole) for the attachment of
SYDFE.-2X (size 71 and size 100, flange C) A10VO..31 (size 71 and size 100, flange C, see data sheet 92701) PGH5 (shaft R, flange U2, see data sheet 10223)
Sectional presentation with examples for hubs (order number for hubs see hubs for through-drives)
Dimensions in mm
Size |
A1 |
A2 |
A3 |
A4 |
A5 |
A6 |
A7 |
mm |
mm |
mm |
mm |
mm |
mm |
||
71 | 267 | 55.5 | 17.9 | 61 | - | - | M16; 18 deep |
100 | 338 | 57 | 17.9 | 65 | 8 | 65 | M16; 25 deep |
140 | 350 | 60 | 17.9 | 77 | 9 | 77.3 | M16; 32 deep |
KC6
Flange SAE 152-4 (SAE D, 4-hole) for the attachment of
SYDFE.-2X (size 140, flange D) A10VO..31 (size 140, flange D, see data sheet 92701)
Sectional presentation with examples for hubs (order number for hubs see hubs for through-drives)
Dimensions in mm
Size |
A1 |
A3 |
A4 |
A5 |
mm |
mm |
mm |
||
140 | 350 | 10.5 | 77 | M16; 24 deep |
Dimensions in mm
Project planning information
Always shield command and actual value cables. The distance to aerial lines or radios must be at least 1 m. Do not lay signal lines close to power lines. For amending notes on the SYDFE control system, see the operating instructions (see section "More information about this control system").Torsionally flexible couplings for attachment to a standard electric motor
Motor |
SYDFE.-2X |
|||
Frame size/characteristic |
Shaft diameter |
NG18 Shaft S, 3/4” |
NG28 Shaft S or R, 7/8″ |
NG45 Shaft S or R, 1″ |
100/0 112/0 |
28 |
R901038012 |
R901038017 |
|
132/0 |
38 |
R900704699 |
R901012344 |
R900772898 |
160/0 |
42 |
R900726977 |
R900991864 |
R900994283 |
180/0 |
48 |
R900032918 |
R900062159 |
|
200/0 |
55 |
R901038026 |
R901038025 |
|
225/0 |
60 |
R900750847 |
R901066409 |
|
250/0 |
65 |
R900988348 |
Motor |
SYDFE.-2X |
|||
Frame size/characteristic |
Shaft diameter |
NG71 Shaft S or R, 1 1/4" |
NG100 Shaft S, 1 1/2" |
NG140 Shaft S, 1 3/4" |
160/0 |
42 |
R900228413 |
||
180/0 |
48 |
R900240468 |
R900242567 |
|
200/0 |
55 |
R901038021 |
R901104689 |
R901038048 |
225/0 |
60 |
R900228375 |
R901050508 |
R900988121 |
250/0 |
65 |
R900986404 |
R901046864 |
R900708084 |
280/0 |
75 |
R900218487 |
R901055216 |
R901052451 |
315/0 |
80 |
R9010468941) |
R9010468301) |
|
315/1 |
80 |
R901046885 |
1) | Up to 40 °C |
Accessories
Version 12/2014, enquire availability
Card holder
VT 3002-2X
Card holder
VT 3002-2X
Component series 2XData sheet
Configurator / CAD
Spare parts & repair
External control electronics for the SYDFE1 control of the A10VSO axial piston variable displacement pump
VT 5041
External control electronics for the SYDFE1 control of the A10VSO axial piston variable displacement pump
VT 5041
Version Analog, Euro-card formatData sheet
Spare parts & repair
Related Products
R901106262
$509.00 USD
R901125068
$621.00 USD
R900538904
$3,527.00 USD
R901057058
$1,741.00 USD
R961008833
$898.33 USD